Safety Precautions

1.5.1.
This product is designed for Indoor use, and for operation in a clean, dry environment.
1.5.2.
This product is designed for pollution degree 1.
1.5.3.
This product is designed for Transient Overvoltage Category II.
1.5.4.
Ensure all covers are in place and securely fastened before switching ON the AC
power.
1.5.5.
Ensure that no liquids or foreign objects are allowed to enter the unit via the chassis
ventilation holes.
1.5.6.
Do not operate near flammable gases or vapors.
1.5.7.
Proper grounding from the input AC power is required to reduce the risk of electric
shock. Ensure that the AC Protective Earth Ground connection has at least the same
gauge wire as the supply leads.
1.5.8.
Use extreme caution when connecting AC input power, and never apply the incorrect
input voltage, refer to ratings label.
1.5.9.
Use extreme caution when connecting the high voltage output cable to the load.
1.5.10. Never handle the output cable when the power supply is operating.
1.5.11. Never attempt to operate the power supply in any manner not described in this
manual.
1.5.12. Never remove DANGER and WARNING labels from the power supply. Replace lost
or damaged labels immediately.
1.5.13. The power supply should only be serviced by factory authorized personnel.
1.5.14. No user maintenance is required.
ALL PHV POWER SUPPLIES ARE DESIGNED TO MINIMIZE THE
RISK OF FIRE OR SHOCK HAZARD. THIS INSTRUMENT RECEIVED
COMPREHENSIVE MECHANICAL AND ELECTRICAL INSPECTION
PRIOR
TO
SHIPMENT.
PRECAUTIONS
MUST
QUALIFIED
SERVICE
PRINCIPLES OF ELECTRICAL SAFETY SHOULD OPERATE THIS
SUPPLY. THE POWER SUPPLY SHOULD NOT BE EXPOSED TO
WATER OR MOISTURE OR DUSTY ENVIRONMENTS. ELECTRICAL
SAFETY MUST BE MAINTAINED AT ALL TIMES.
LETHAL VOLTAGES ARE PRESENT WITHIN THE POWER SUPPLY'S
ENCLOSURE AND AT THE OUTPUT CABLE. THEREFORE, THE
COVER MAY NOT BE REMOVED BY THE USER. THE LARGE
CAPACITORS IN THE SUPPLY MAY STORE POWER EVEN AFTER
THE AC INPUT LINE IS REMOVED. ALLOW AT LEAST 5 MINUTES
DISCHARGE TIME BETWEEN REMOVING THE AC INPUT LINE AND
OPENING THE COVER. ALSO, ALLOW AT LEAST 40 SECONDS
BETWEEN SWITCHING THE AC POWER OFF AND SWITCHING IT
ON AGAIN.