TDK-Lambda PHV Series Operator's Manual
TDK-Lambda PHV Series Operator's Manual

TDK-Lambda PHV Series Operator's Manual

High voltage power supply
Hide thumbs Also See for PHV Series:
Table of Contents

Advertisement

Quick Links

OPERATOR MANUAL FOR
PHV Series High Voltage
POWER SUPPLY
Document: 83550001 Rev C
TDK-LAMBDA AMERICAS
405 Essex Road, Neptune, NJ 07753
Tel:
(732) 922-9300
Fax:
(732) 922-9334
Web: www.us.tdk-lambda.com/hp

Advertisement

Table of Contents
loading

Summary of Contents for TDK-Lambda PHV Series

  • Page 1 OPERATOR MANUAL FOR PHV Series High Voltage POWER SUPPLY Document: 83550001 Rev C TDK-LAMBDA AMERICAS 405 Essex Road, Neptune, NJ 07753 Tel: (732) 922-9300 Fax: (732) 922-9334 Web: www.us.tdk-lambda.com/hp...
  • Page 2 THREE YEAR WARRANTY TDK-Lambda Americas, Inc. (405 Essex Road, Neptune, N.J. 07753), warrants that the unit is free from defects in material or workmanship for a period of THREE YEARS from the date of initial shipment. TDK-Lambda Americas Inc. will service and, at its option, repair or replace parts which prove to be defective. This will be done free of charge during the stated warranty period.
  • Page 3 TDK-Lambda Description of symbols used in product labeling SYMBOL PUBLICATION DESCRIPTION EC Council European Community Directive 93/68/EEC Conformity Assessment Product Mark IEC 348 Attention, consult Accompanying documents IEC 60417-1-5036 Dangerous voltage IEC 60417-1-5019 Protective earth (e.g. power line earth ground)
  • Page 4: Table Of Contents

    1.6. Model Number Format ......................7 SPECIFICATION........................8 OUT OF BOX INSPECTION ....................10 3.1. Visual Inspection ........................10 3.2. Contacting TDK-Lambda Americas Customer Service ............10 3.3. Returning Defective Units ......................10 INSTALLATION ........................12 4.1. 19-Inch Rack Mounting ......................12 4.2. Ventilation Requirements ......................12 4.3.
  • Page 5 5.1.20. Analog LED (Ref 20) .......................20 5.1.21. Analog/Digital Remote Switch (Ref 21) ..................20 5.1.22. Digital LED (Ref 22) ........................20 5.1.23. Busy LED (Ref 23) ........................20 5.2. Rear Panel Layout ........................20 5.2.1. HV Output Connector (Ref 1) ....................22 5.2.2. HV Output Return (Ref 2) ......................22 5.2.3.
  • Page 6 List of Figures Figure 1. PHV Front Panel Controls and Indicators ................16 Figure 2. PHV Half Rack Rear Panel Connections (140Watt model with floating return shown) ..20 Figure 3. PHV Half Rack Rear Panel with Reversible Output ............. 21 List of Tables Table 1.
  • Page 7: General Information

    1.2. Introduction TDK-Lambda PHV series are state of the art precision switch mode high voltage power supplies, designed to provide a highly stable, low ripple HV DC output for a broad range of applications including photomultipliers, Ion sources, Insulation testing, Electron Microscopy, and a multitude of other applications requiring precise and stable DC power.
  • Page 8: Phv Overview

    1.3. PHV Overview 1.3.1. Features  11 power ranges from 14Watts to 15,000Watts.  Output voltages from 0-125V to 0-300,000V in 16 ranges.  Local or remote operation with optional Analog or Digital control interface.  Comprehensive range of available digital interfaces including LAN, IEEE, USB. ...
  • Page 9: Safety Precautions

    1.5. Safety Precautions ALL PHV POWER SUPPLIES ARE DESIGNED TO MINIMIZE THE RISK OF FIRE OR SHOCK HAZARD. THIS INSTRUMENT RECEIVED COMPREHENSIVE MECHANICAL AND ELECTRICAL INSPECTION PRIOR SHIPMENT. NEVERTHELESS, CERTAIN SAFETY PRECAUTIONS MUST OBSERVED. ONLY TECHNICALLY QUALIFIED SERVICE PERSONNEL FAMILIAR WITH PRINCIPLES OF ELECTRICAL SAFETY SHOULD OPERATE THIS SUPPLY.
  • Page 10: Model Number Format

    1.6. Model Number Format The model numbering system for the PHV Series power supply includes symbols for features and options. They are separated by dashes. Examples are: PHV2P6-LAN-1P115 and PHV20N200-USB-3P208 Table 1 shows a partial listing of the model description format for the PHV Power Supply family.
  • Page 11: Specification

    2. SPECIFICATION 83550001 Revision C...
  • Page 12 Mechanical Details 83550001 Revision C...
  • Page 13: Out Of Box Inspection

    Normally, the customer may NOT open any chassis covers that have a warranty seal. Breaking a seal will void the warranty. At the discretion of TDK-Lambda Americas, the customer may be granted permission to break the warranty seal and open the chassis covers. Customer Service shall confirm the permission by sending a replacement seal.
  • Page 14 This Page Left Intentionally Blank 83550001 Revision C...
  • Page 15: Installation

    DAMAGE WILL RESULT, THAT COVERED BY TDK-LAMBDA AMERICAS STANDARD WARRANTY. The unit is equipped with a protective earth in the AC connector or terminal block. For protection against electric shocks, the unit must be connected to the AC power via a suitable 3 or 5-pole cable with a non-fused earth conductor.
  • Page 16: High Leakage Current

    For single phase models (≤1400Watt output power) AC power connectors are; 14Watts to 350Watts Models - IEC 60320-C14 700Watt models - IEC 60320-C19 For power levels greater that 700Watts, Phoenix HDFK4 terminal blocks are provided. Use extreme caution when connecting input AC power and never apply the incorrect input power.
  • Page 17: Connecting The High Voltage Output

    Before connecting the HV output cable, inspect the cable and check for signs of damage. Always use the HV connector and cable provided with the power supply or an equivalent substitute provided by TDK-Lambda Americas. The shield of the HV cable or a separate conductor connected between the ground stud on the unit and the load can be used for the return connection.
  • Page 18: Table 2. Phv Hv Output Connector Types

    Note 1. PHV0.65P15000, PHV0.65P22500, and PHV1.25P12000, use GES S115 connector with GES cable 3330005 due to the high output current. Note 2. Connectors and cable are GES designs available from TDK-Lambda. Note 3. Connectors and cable available from TDK-Lambda Note 4. Additional cable is available from TDK-Lambda Table 2.
  • Page 19: Controls, Indicators, Connectors

    5. CONTROLS, INDICATORS, CONNECTORS 5.1. Front Panel Layout The PHV series power supply is equipped with a fully instrumented front panel featuring output voltage/current controls, voltage and current metering, and comprehensive status LEDs, along with local/remote mode switch , and power on switch. The PHV can be...
  • Page 20: Table 3. Front Panel Controls And Indicator Functions (Includes Optional Features)

    DESCRIPTION NOTE SECTION Overtemp LED Indicates an Overtemperature condition 5.1.1 P-Limit LED Illuminated for optional Power limit mode 5.1.2 Indicates actual output voltage, displays set point when Voltage Display 5.1.3 flashing CV LED Illuminated for Constant-Voltage mode operation 5.1.4 Output Voltage Lockable 10-turn Potentiometer for output voltage set value 5.1.5 Control...
  • Page 21: Overtemp Led (Ref 1)

    The front panel controls/indicators are described in detail in the following sub-sections. 5.1.1. Overtemp LED (Ref 1) Indicates the internal thermal sensor has detected an Overtemperature condition. Causes are excessive ambient temperature, fan failure, poor ventilation, or excessive accumulated dust. Allow unit to cool and cycle power OFF/ON to reset the fault. Ensure cooling vents are clear and clearance around the unit meets the requirements shown in 4.2.
  • Page 22: Cc Indicator Led (Ref 9)

    5.1.9. CC Indicator LED (Ref 9) Indicates the unit is in CC (Constant Current) mode. The power supply regulates the output current at the selected value, while the voltage varies with the load requirement. Display is active in local and remote modes.
  • Page 23: Analog Led (Ref 20)

    5.1.20. Analog LED (Ref 20) Indicates that a supply equipped with both remote analog and digital interfaces is operating in remote control mode via the Analog interface. 5.1.21. Analog/Digital Remote Switch (Ref 21) Toggles the control mode of a supply equipped with both remote analog and digital interfaces between the remote Analog or Digital interface.
  • Page 24: Figure 3. Phv Half Rack Rear Panel With Reversible Output

    DESCRIPTION NOTE SECTION HV Output HV Output connector, mates with supplied connector 5.2.1 HV Return HV Output Return 5.2.2 Digital Interface Location of optional digital interface connector 5.2.3 (optional) Remote 15pin sub-D type receptacle for remote analog control 5.2.4 Interface interface ɸ...
  • Page 25: Hv Output Connector (Ref 1)

    5.2.1. HV Output Connector (Ref 1) Main HV output, mates with the connector supplied with the unit. The connector should be kept clean and free from debris at all times. The cable connector should only be hand tightened. The HV output polarity is indicated by a label adjacent to the HV Connector (blue=Negative;...
  • Page 26 This Page Left Intentionally Blank 83550001 Revision C...
  • Page 27: Local Operation

    6. LOCAL OPERATION HIGH VOLTAGES MAY POTENTIALLY EXIST FROM THIS POINT FORWARD. ENSURE HV OUTPUT IS IN THE OFF POSITION BEFORE COMMENCING. Follow the steps below to operate the PHV supply in Local mode. 6.1. Set the Control Mode If an optional interface is installed, ensure front panel LOCAL/REMOTE switch is depressed and the unit is in Local Mode (Item 18 in Figure 1).
  • Page 28: Cc/Cv Mode Indication

    6.7. CC/CV Mode Indication Depending on the output voltage and current settings and the load circuit, the power supply will operate in either constant voltage CV or constant current mode CC and the corresponding LED (Item 3 or 8 in Figure 1) will be illuminated. 6.8.
  • Page 29: Analog Remote Control Operation

    7. ANALOG REMOTE CONTROL OPERATION All remote control cabling should be as short as possible with a maximum length of 10ft (3.3m). To control the PHV supply using Analog remote programming, the unit must be equipped with either the non-isolated Analog interface or the isolated Analog interface options (INA). A unit equipped with the isolated analog interface has a label or engraving “FLOATING ANALOG PROGRAMMING”...
  • Page 30: Typical Remote Operation

    Description Signal Name Analog Analog ground Ground +10V +10V reference, 2mA max V-MON Analog output voltage monitor signal, scaled 0-10V=0-100% rated voltage. Series resistance is 10k HV ON Open=HV OFF, Connect to digital ground=HV ON POL- Output Polarity indicator for units equipped with optional electronic Status polarity reversal.
  • Page 31: Isolated Analog Programming (Ina Option)

    7.2. Isolated Analog Programming (INA option) The INA option features galvanically isolated analog voltage/current programming/readback, and digital control/readback connections. Signals are isolated using fiber optics. The Accuracy, Linearity, Temperature coefficient and Stability specifications are limited to ±0.01% when programming via the isolated analog interface. If the unit is equipped with floating return, the isolated analog interface should be specified.
  • Page 32 This Page Left Intentionally Blank 83550001 Revision C...
  • Page 33: Digital Remote Control Operation

    8. DIGITAL REMOTE CONTROL OPERATION The PHV series is available with a wide range of optional digital control interfaces. The interface must be specified at the time of ordering. The digital interface connector is located on the rear panel of the unit (see Figure 2 and Figure 3).
  • Page 34 This Page Left Intentionally Blank 83550001 Revision C...
  • Page 35: Parallel Operation

    9. PARALLEL OPERATION Parallel operation of units with the same voltage and current ratings is possible using the non-isolated analog interface. The interface must be installed on both units. Parallel Master Slave operation with the Remote Analog Interface – Option 1 9.1.
  • Page 36 This Page Left Intentionally Blank 83550001 Revision C...
  • Page 37 Notes 83550001 Revision C...
  • Page 38 If there are any other application issues or questions that are not covered in this manual, please do not hesitate to contact the factory and our team of experienced HV application engineers. Contact the Factory – We are here to help! Tel: +1 732 922 9300 x229 Fax: +1 732 922 1441 83550001 Revision C...