Field Settings Table - Daikin EKHVWQ002AAV3 Operation Manual

Domestic hot water heat pump
Hide thumbs Also See for EKHVWQ002AAV3:
Table of Contents

Advertisement

6.2. Field settings table

First
Second
code
code
Setting name
0
Different operation modes
00
Powerfull operation mode temperature set point
01
Disinfection operation mode tempeature set point
02
Temperature setpoint: reheat minimum
temperature
03
Temperature setpoint: reheat maximum
temperature
04
Status: defines whether the reheat operation is
turned ON(1) or OFF(0)
1
Automatic domestic hot water tank temperature set point calculation
00
Renewal time for set point calculation
01
Mnimum automatic temperature set point
02
Maximum automatic temperature set point
2
Disinfection operation
00
Installation related setting
01
Installation related setting
02
Installation related setting
03
Installation related setting
04
Installation related setting
3
Miscellaneous
00
Installation related setting
01
Installation related setting
02
Installation related setting
03
Installation related setting
4
Miscellaneous
03
Installation related setting
04
Installation related setting
6
Miscellaneous
00
Installation related setting
01
Installation related setting
02
Installation related setting
03
Installation related setting
04
Installation related setting
7
Miscellaneous
01
Installation related setting
02
Installation related setting
03
Installation related setting
04
Installation related setting
8
Automatic setpoint calculation
00
Installation related setting
01
Installation related setting
02
Installation related setting
03
Installation related setting
04
Installation related setting
D
Benefit kWh rate power supply/Local shift value weather dependent
01
Installation related setting
E
Unit information readout
00
Installation related setting
01
Installation related setting
02
Installation related setting
Operation manual
15
Installer setting at variance with default value
Date
Value
Date
Default
Value
value
Range
40
35~50
60
55~75
40
35~75
45
35~75
0 (OFF)
0/1
6:00
0:00~23:30
42
35~75
60
35~75
Fri
1 (ON)
23:00
0 (OFF)
32
1 (ON)
3
0 (OFF)
0 (OFF)
0
1
10
0
0
1 (ON)
1
2
3
0
2
45
50
15
0 (OFF)
0 (260 l)
0
EKHVWQ002AAV3 + EKHHS200+260AA1V3
Domestic hot water heat pump
Step
Unit
1
°C
1
°C
1
°C
1
°C
1
0:30
hour
1
°C
1
°C
4PW65343-1A – 10.2010

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ekhhs200aa1v3Ekhhs260aa1v3

Table of Contents