Fisher FSKIF-121AE2-EU Service Manual page 146

Super dc inverter lcac series
Hide thumbs Also See for FSKIF-121AE2-EU:
Table of Contents

Advertisement

Troubleshooting
2.4.4.4. F1, F2, F3 malfunction
Error
E4 display
Judge 1: Outdoor condenser temp. sensor (T3) is malfunction
Check whether the wiring of the 
condenser temp. sensor(T3) is 
broken off
Check whether the resistance of 
condenser temp. sensorT3) is wrong 
refer to the Appendix 1
Judge 2: Outdoor ambient temp. sensor (T4) is malfunction
Check whether the wiring of the 
outdoor ambient temperature 
sensor (T4) is broken off
Check whether the resistance of 
outdoor ambient temperature 
sensor (T4) is wrong refer to the 
Appendix 1
Judge 3: Compressor discharge temp. sensor (T5) is malfunction
Check whether the wiring of the 
compressor discharge temperature 
sensor (T5) is broken off
Check whether the resistance of 
compressor discharge temp. sensor 
(T5) is wrong refer to the Appendix 2
Replace outdoor main PCB
142
Yes
No
Yes
No
Yes
No
Yes
No
No
No
F1
Connect the wiring well
Replace condenser temp. sensor(T3)
F2
Connect the wiring well
Replace outdoor ambient 
temperature sensor (T4)
F3
Yes
Connect the wiring well
Replace compressor discharge 
Yes
temperature sensor (T5)
Electrical Control System