2.3 Outdoor unit malfunction
For 18~60K:
Display
E1
Communication malfunction between indoor and outdoor units
F0
Overcurrent protection
F1
Ambient temperature sensor (T4) is malfunction
F2
Outdoor heat-exchanger temperature sensor (T3) is malfunction
F3
Discharge temperature sensor (T5) is malfunction
F4
Outdoor EEPROM is malfunction
F5
Outdoor fan speed has been out of control
P0
IPM module protection
P1
Voltage protection (too high or too low)
P3
Protection of ultra-low ambient temperature
P4
Rotor position protection of compressor
J0
High temperature protection of indoor heat exchanger in heating mode
J1
High temperature protection of outdoor heat exchanger in cooling mode
J2
High discharge temperature protection
J3
PFC module protection
J4
Communication error between outdoor main chip and compressor driven chip IR341
J5
High pressure protection
J6
Low pressure protection
P7
IGBT sensor is malfunction
J8
AC voltage protection
In low ambient cooling mode, the LED displays"LC" or alternative displays between running frequency
and "LC"(each displays 0.5s)
Electrical Control System
Malfunction or Protection
Troubleshooting
131