INSTALLATION INSTRUCTIONS

R
U
ECEIVING AND
1. Inspect the carton and note any damage, regardless if it appears minor. If the carton is damaged, note on
the consignee copy of the freight invoice "exterior carton damage – concealed damage possible".
2. Cut the banding strap and remove the exterior carton sleeve, internal fillers and plastic bag around the
dispenser. Carefully inspect for damage.
NOTE: IMI Cornelius is not responsible for damaged freight. If damage is found, you must save all
packaging material and contact the freight carrier. Failure to contact the carrier within 48 hours of
receipt may void your claim.
I
NSTALLATION
1. Typically the dispenser is placed directly on the counter and a food grade silicone sealant is applied around
the base. However, the legs that are included with the dispenser may be used. The following instructions
assume the legs will not be used.
2. Depending on the type of counter, it may be necessary to provide access through the counter at the rear of
the dispenser for the drain, power, water and concentrate connections.

Installation Kit P/N 629087473

Item
Part Number
1
300423000
2
31525016
3
50119
4
70339
5
620919546INS
6
620920205 thru 10
3. With the assistance of another person, lift the dispenser using the base and place it on the counter.
NOTE: The dispenser is extremely heavy when operational. Make certain the counter can support
a minimum of 300 lbs. directly below the dispenser.
4. Sanitizing Prior to Initial Use
The beverage system must be cleaned and sanitized after installation is completed to safeguard against
any possible contaminants that may have entered the system during transport or installation. Refer to the
"Cleaning And Sanitizing" section of this manual for procedures.
5. Connecting the Water Supply
A. Water Pipe Connections and fixtures directly connected to a potable water supply shall be sized,
installed and maintained according to federal, state and local laws.
B. It is recommended that a 1/2" OD copper supply line with a shut–off valve and water filter be located
within 3–6 feet (.9–1.8 m) of the dispenser.
C. Remove the splash panel. Run the water supply line through the hole in the back of the base marked
"water" and up the front of the unit to the water inlet fitting located behind the splash panel.
D. Connect the 3.8" ID supply line to water supply with a 3/8" barb fitting.
E. When installing the splash panel, attach the ground wire, at the water bath front, to the splash panel
grounding tab.
NOTE: The dynamic water pressure must be 20 psig (1.3 Bar) minimum to ensure correct valve
flow control and must not exceed 100 psig to avoid valve damage.
Publication Number: 620919546INS
NPACKING
Connector Bag-N-Box 375
O-Ring 614ID 070CS
Hose Plastic 5.8ID X 1/8 Wall
Clamp Hose
Manual Installation Millennium 6V
Flavor Strip Assorted #1 thru #6
Description
- 4 -
Qty.
6
1
5 ft.
1
1
6
© 2003-2012, IMI Cornelius Inc.