Siemens SITRANS LG270 Operating Instructions Manual page 83

Guided wave radar
Table of Contents

Advertisement

Shock resistance
Ʋ Instrument housing
Ʋ Rod probe
Electromechanical data - version IP 66/IP 67
Cable gland
Wire cross-section (spring-loaded terminals)
Ʋ Massive wire, cord
Ʋ Stranded wire with end sleeve
Display and adjustment module
Display element
Measured value indication
Ʋ Number of digits
Ʋ Size of digits
Adjustment elements
Protection rating
Ʋ unassembled
Ʋ mounted into the housing without
cover
Materials
Ʋ Housing
Ʋ Inspection window
Integrated clock
Date format
Time format
Time zone Ex factory
Rate deviation max.
Measurement electronics temerature
Resolution
Accuracy
Voltage supply
Operating voltage
Power consumption
Interpolation protection
Electrical protective measures
Protection, depending on housing version
Ʋ Plastic housing
PBD-51041066
100 g, 6 ms according to EN 60068-2-27 (mechanical
shock)
25 g, 6 ms according to EN 60068-2-27 (mechanical
shock) with rod length 50 cm (19.69 in)
M20 x 1.5 or ½ NPT
0.2 ... 2.5 mm² (AWG 24 ... 14)
0.2 ... 1.5 mm² (AWG 24 ... 16)
Display with backlight
5
W x H = 7 x 13 mm
4 keys
IP 20
IP 40
ABS
Polyester foil
Day.Month.Year
12 h/24 h
CET
10.5 min/year
1 °C (1.8 °F)
±1 °C (1.8 °F)
8 ... 30 V DC
< 500 mW
Integrated
IP 66/IP 67 (NEMA 4X)
SITRANS LG270 - Operating Instructions
83