7.10

Difficult breakdowns

7.10.1 The board does not respond, the TC does not turn on
Verify that the board is receiving power.
Check the connection between the touch control and the
ELIN.
If the preceding is correct, proceed as follows:
Remove the connection between the right and left ELIN (CNT4 and
CNT4).
In the event that the burners on the left do work, replace the right
ELIN.
If the failure persists, change the touch control.
If it still does not work, reinstall the original touch control and change
the left ELIN.
7.10.2 Fan failure
After detecting a fan error (e2) and subsequently replacing the fan, if
the error persists, then replace the right board and reinstall the original
fan.