Excell ZSME300000240 User Manual page 15

Weighing scale 4key & 5key
Table of Contents

Advertisement

EXCELL PRECISION CO., LTD.
HEAD1 ( 2 BYTES )
OL -
Overload , Under load
ST -
Display is Stable
US -
Display is Unstable
DATA ( 7 or 8 BYTE )
2B ( HEX ) = " + " ( PLUS)
2D ( HEX ) = " – " ( MINUS )
2E ( HEX ) = " . " ( DECIMAL POINT )
UNIT ( 2、3 or 4 BYTE )
kg
=
6B ( HEX )
lb
=
6C( HEX )
tl.T
=
74 ( HEX )
hkg =
68 ( HEX )
viss =
76 ( HEX )
Transmission examples:
Data format for
1. The gross weight (+0.876 kg) shows as below, after stable: (under tare mode)
S
T
,
G
S
HEAD1
, HEAD2
2. The net weight (-1.568 lb) shows as below without weight stability: (under no tare mode)
U
S
,
N
T
HEAD1
, HEAD2 ,
3. The net weight (+15.0624 HK tael) shows as below, after stable: (under no tare mode)
S
T
,
N
T
HEAD1
, HEAD2
4. The net weight (+1.245 viss) shows as below, after stable: (under tare mode)
S
T
,
T
R
HEAD1
, HEAD2
02018058
HEAD2 ( 2 BYTES )
TR -
NT -
GS -
; 67 ( HEX )
; 62 ( HEX )
; 6C ( HEX )
; 67 ( HEX )
; 69 ( HEX )
RS-232 continuous transmission are as below:
,
+
,
,
-
,
+
1
5
.
,
,
+
1
,
DATA
TARE Mode
NET Mode
GROSS Mode
2E ( HEX )
73 ( HEX )
0
.
8
7
6
DATA
1
.
5
6
8
DATA
0
6
.
2
4
DATA
.
2
4
5
v
13
54 ( HEX )
73 ( HEX )
k
g
0D 0A
UNIT C
LF
l
b
0D 0A
UNIT
C
LF
h
k
g 0D 0A
UNIT
C
LF
i
s
s 0D 0A
UNIT
C
LF