Mounting The Device; Dimension Drawings - Siemens RUGGEDCOM M969 Installation Manual

Table of Contents

Advertisement

Chapter 2
Installing the Device
Section 2.6, "Ingress Protection"
Section 2.1

Mounting the Device

The RUGGEDCOM M969 is designed to be mounted on a panel by affixing the top and bottom flanges of the
device to a panel using screws.
IMPORTANT!
Heat generated by the device is channeled outwards to the enclosure. As such, it is recommended that
2.5 cm (1 in) of space be maintained on all open sides of the device to allow for some convectional
airflow.
Forced airflow is not required. However, any increase in airflow will result in a reduction of ambient
temperature and improve the long-term reliability of all equipment mounted in the rack space.
NOTE
For detailed dimensions of the device with panel mount hardware installed, refer to

Dimension Drawings

To mount the device to a panel, do the following:
1.
Place the device against the panel and align the flanges with the mounting holes.
Figure 3: Panel Mounting (Typical)
1. Flange
8
.
1
RUGGEDCOM M969
Installation Guide
Chapter 5,
Mounting the Device