Gigabit Ethernet Optical Specifications; Operating Environment; Mechanical Specifications - Siemens RUGGEDCOM M969 Installation Manual

Table of Contents

Advertisement

RUGGEDCOM M969
Installation Guide
Section 4.4.2

Gigabit Ethernet Optical Specifications

NOTE
• All cabling is duplex type unless otherwise specified.
• Maximum segment length is greatly dependent on factors such as fiber quality, and the number
of patches and splices. Consult a Siemens sales associate when determining maximum segment
distances.
• All optical power numbers are listed as dBm averages.
Mode
Connector
MM
LC
SM
LC
SM
LC
d
Typical.
Section 4.5

Operating Environment

Parameter
Ambient Operating Temperature
Ambient Relative Humidity
Ambient Storage Temperature
IP Rating
Operating Altitude
e
Reduced to -40 to 80 °C (-40 to 76 °F) when equipped with a 100Base-FX, single-mode, 1300 nm, long-reach 90 km port(s).
Section 4.6

Mechanical Specifications

Dimensions
Weight
Ingress Protection
Gigabit Ethernet Optical Specifications
Cable
d
Tx λ (nm)
Type (µm)
50/125
850
62.5/125
8/125
1310
9/125
8/125
1310
9/125
Range
-40 to 85° C (-40 to 185° F)
5% to 95%
-40 to 85° C (-40 to 185° F)
IP67
0 to 15240 m (0 to 50000 ft)
Refer to
Chapter 5, Dimension Drawings
2.86 kg (6.3 lb)
IP65, IP67
Tx Pwr
Rx
(dBm)
Sensitivity
(Min/Max)
(dBm)
-9.5/-4
-20
-9.5/-3
-22
-7/3
-26
Comments
e
Ambient Temperature as measured from a 30 cm (12 in.) radius
surrounding the center of the RUGGEDCOM M969 enclosure.
Non-condensing
Over temperature range of -40 to 85° C (-40 to 185° F)
Technical Specifications
Rx
Typical
Saturation
Distance
(dBm)
(km)
0
0.5
-3
10
-3
25
Chapter 4
Power
Budget (dB)
14
17
19
23

Advertisement

Table of Contents
loading

Table of Contents