Pressure sensor characteristics
Input / output wiring summary
High pressure side (PD)
Pin No.
Input / output name
1
OUTPUT
2
3
GND
4
+5 V
Output voltage vs. pressure
H
g i
h
p
e r
s
s
u
e r
0.5
~
4.3 V
0
3.73 MPa
~
Pressure (MPa)

Indoor Unit

Temperature sensor characteristics
Indoor TA sensor
Resistance
[k ]
Lead wire color
White
Black
Red
s
d i
e
P (
) D
Temperature [°C]
Low pressure side (PS)
Input / output name
OUTPUT
GND
+5 V
L
o
w
p
e r
s
s
u
e r
s
d i
e
0.5
~
3.5 V
0
0.98 MPa
~
148
157
Lead wire color
White
Black
Red
P (
) S
Pressure (MPa)
Temperature [°C] Resistance [k ]