Electrolux WTCS90ERB Service Manual page 30

Modular and compact rack-type dishwashers
Table of Contents

Advertisement

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
List of events documented by the DATALOG:
Event
Event name
number
1
BOIL. TEMP. HIGH
2
DUO TEMP. HIGH
3
WASH. TEMP. HIGH
4
PREW. TEMP. HIGH
5
DT TEMP. HIGH
6
BOIL. TEMP. LOW
7
DUO TEMP. LOW
8
WASH TEMP. LOW
9
DT TEMP. LOW
11
AIRG. FILL. TOUT
12
AIRG. LEV. FAULT
13
DUO FILL. TOUT
14
DUO LEV. FAULT
15
BOIL. HEAT. TOUT
16
BOILER OVERTEMP.
17
BOILER NTC SHORT
18
BOILER NTC OPEN
19
DUO HEAT. TOUT
20
DUO OVERTEMP.
21
DUO NTC SHORT
22
DUO NTC OPEN
23
RIN. PUMP THERM.
24
DUO PUMP THERM.
25
DRAIN DUO TOUT
27
INVERTER ERROR
30
DRAIN AIRG TOUT
31
WASH FILL. TOUT
32
WASH LEV. FAULT
33
WASH HEAT. TOUT
DOC. NO. 5956.573.05
Event description
The boiler temperature has exceeded the temperature set point
by 7 °C/13 °F.
The duo rinse temperature has exceeded the temperature set
point by 8 °C/14 °F.
The wash tank temperature has exceeded the temperature set
point by 8 °C/14 °F.
The prewash tank temperature has exceeded the temperature
set point by 35 °C/63 °F.
The dry tunnel temperature has exceeded the temperature set
point by 15 °C/27 °F.
During the wash phase the boiler temperature has decreased
by more than 12 °C/25 °F with respect to the permissible min.
value (– hysteresis temperature set point).
During the wash phase the duo rinse temperature has decreased
by more than 15 °C/27 °F with respect to the permissible min.
value (–hysteresis temperature set point).
During the wash phase the wash tank temperature has
decreased by more than 15 °C/27 °F with respect to the
permissible min. value (–hysteresis temperature set point).
During the wash phase the dry tunnel temperature has
decreased by more than 15 °C/27 °F with respect to the
permissible min. value (–hysteresis temperature set point).
Alarm number 11 has occurred:
The Air Gap was not completely filled within the max. filling time.
Alarm number 12 has occurred:
The pressure sensor on the rinse module electronic board does
not work correctly.
Alarm number 13 has occurred:
The Duo-rinse tank was not completely filled within the max.
filling time.
Alarm number 14 has occurred:
The pressure sensor on the Duo-rinse tank does not work
correctly.
Alarm number 15 has occurred:
The required temperature was not reached in the boiler within the
max. heating time.
Alarm number 16 has occurred:
The water temperature in the boiler is too high
Alarm number 17 has occurred:
The boiler temperature sensor is short circuited.
Alarm number 18 has occurred:
The boiler temperature sensor is open.
Alarm number 19 has occurred:
The required temperature was not reached in the Duo-rinse tank
within the max. heating time.
Alarm number 20 has occurred:
The water temperature in the Duo-rinse tank is too high.
Alarm number 21 has occurred:
The Duo-rinse tank temperature sensor is short circuited.
Alarm number 22 has occurred:
The Duo-rinse tank temperature sensor is open.
Alarm number 23 has occurred:
SHORT COMPACT AND MODULAR: The rinse pump thermal
protector has tripped.
Alarm number 24 has occurred:
The Duo-rinse pump thermal protector has tripped.
Alarm number 25 has occurred:
The Duo-rinse tank was not completely emptied within the max.
emptying time.
Alarm number 27 has occurred:
The motor control inverter has generated an error.
Alarm number 30 has occurred:
The Air gap was not completely emptied within the max.
emptying time.
Alarm number 31 has occurred:
The wash tank was not completely filled within the max. filling
time.
Alarm number 32 has occurred:
The pressure sensor on the wash tank does not work correctly.
Alarm number 33 has occurred:
The required temperature in the wash tank was not reached
within the max. heating time.
Event value (VALUE)
Indicates the boiler temperature at the time
of event recording.
Indicates the duo rinse temperature at the
time of event recording.
Indicates the wash tank temperature at the
time of event recording.
Indicates the prewash temperature at the
time of event recording.
Indicates the dry tunnel temperature at the
time of event recording.
Indicates the boiler temperature at the time
of event recording.
Indicates the duo rinse temperature at the
time of event recording.
Indicates the wash tank temperature at the
time of event recording.
Indicates the dry tunnel temperature at the
time of event recording.
Indicates the air gap level at the time of
event recording.
Indicates the air gap level at the time of
event recording.
Indicates the duo rinse level at the time of
event recording.
Indicates the duo rinse level at the time of
event recording.
Indicates the boiler temperature at the time
of event recording.
Indicates the boiler temperature at the time
of event recording.
Not significant
Not significant
Indicates the duo rinse temperature at the
time of event recording.
Indicates the duo rinse temperature at the
time of event recording.
Not significant
Not significant
Not significant
Not significant
Indicates the duo rinse level at the time of
event recording.
Indicates the selected speed at the time of
event recording.
Indicates the airgap level at the time of event
recording.
Indicates the wash tank level at the time of
event recording.
Indicates the wash tank level at the time of
event recording.
Indicates the wash tank temperature at the
time of event recording.
P. 30 / 88