Electrolux WTCS90ERB Service Manual page 16

Modular and compact rack-type dishwashers
Table of Contents

Advertisement

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
Modular
Compact
parameter
parameter

Buzzer
enabled.

Demo
mode

Rinse
autostart.
***
Max.
motor
***
curr.

Set
default
par.
(*) For the other equipment families, see par. B PROGRAMMING SHEETS.
** The table given below indicates the delay between transit of the rack on the autorinse lever and stopping of
the rinse phase.
E.g. in a WTM165 working at high speed (165 racks/h) the rinse pump keeps operating for 11 seconds after
the last rack has released the autorinse lever.
DOC. NO. 5956.573.05
Family
Para
Parameter description
Nr.
meter
Nr.
1
29
Enables machine buzzer.
Modular Rack Type:
- 0/"No" machine buzzer disable
- 1/"Yes" machine buzzer enable.
Compact Rack Type:
- "0" machine buzzer disable
- "1" machine buzzer enable.
1
30
Demo mode.
Modular Rack Type:
- 0/"No demo"
- 1/"Demo mec" the users are not activated and the
inputs are not read, but communication between the
USER card and POWER cards is maintained .
- 2/"Demo user" the users are not activated, the
inputs
are not read, the USER card doesn't communicate
with the POWER cards.
Compact Rack Type:
- "0" normal dishwasher operation.
- "1" the users are not activated and the inputs are not
read, but communication between the USER card
and POWER cards is maintained .
- "2" not available on these models.
1
31
Indicates the type of command for the start of the
rinse phase. It can be set to "Mechanical" (1) only if
the special mechanical lever is present in the rinse
**
zone.
1
32
Indicates the max. current deliverable to the gear
motor by the inverter if the automatic gear motor
current setting procedure was not carried out.
If the supplied current is higher than this value,the
message "CROCKERY STUCK" appears on modular
Rack Type no USA and the message "

" on compact Rack Type.
1
33
It allows all the parameters to be set to their default
value. The set parameters are those of a WTM165
without DT.
The parameter set to "Yes" (1) automatically returns
to "No" (0).
normal operation.

Unit of
Min
Max
Factory
measure
setting
[for
WTM165
(*)]
-
No
Yes
Yes
(0)
(1)
(1)
-
0
1
0
-
-
-
No demo
(0)
-
-
-
0
Sof
Mec
Software/0
twa
hani
re/0
cal/
1
dec
0
40
35
Amp.
-
-
(110Vac
gearmotor)
0
(230Vac
gearmotor)
-
No/
Yes/
No/
0
1
0
P. 16 / 88

Hide quick links:

Advertisement

Table of Contents
loading