MS5027PR

BASIC NEEDLE POSITION

* IF THE LEFT NEEDLE POSITION IN MAXIMUM ZIGZAG AND IN STRAIGHT SEWING ARE NOT THE
SAME, ADJUST AS FOLLOWS:
ADJUSTMENT PROCEDURE:
1.
REMOVE THE BELT COVER (SEE PAGE 9).
2.
SELECT THE LEFT NEEDLE POSITION IN MAXIMUM ZIGZAG, THEN SELECT THE LEFT NEEDLE
POSITION IN STRAIGHT SEWING.
3.
IF THE RESULT LOOKS LIKE (A) SEE BELOW, TURN THE ADJUSTING SCREW IN DIRECTION (D).
IF THE RESULT LOOKS LIKE (B) SEE BELOW, TURN THE ADJUSTING SCREW IN DIRECTION (C).
4.
REPLACE THE BELT COVER (SEE PAGE 8).
ADJUSTING SCREW
NEEDLE POSITION IN
MAXIMUM ZIGZAG
NEEDLE POSITION IN
STRAIGHT SEWING
MECHANICAL ADJUSTMENT
CORRECT
(D)
(C)
(A)
INCORRECT
INCORRECT
32
(B)