2.0 Mount the transmitter

2.1 Mounting in liquid applications
1. Place taps to the side of the line.
2. Mount beside or below the taps.
3. Mount the transmitter so the drain/vent valves are oriented upward.
Figure 2. Liquid Applications
Flow
A
A. Coplanar
B. In-line
2.2 Mounting in gas applications
1. Place taps in the top or side of the line.
2. Mount beside or above the taps.
Figure 3. Gas Applications
Flow
A
A. Coplanar
B. In-line
2.3 Mounting in steam applications
1. Place taps to the side of the line.
2. Mount beside or below the taps.
3. Fill impulse lines with water.
Figure 4. Steam Applications
Flow
A
A. Coplanar
B. In-line