CHAPTER 2. MMC Programming

[204] COMMON BELL CONTROL

Determines whether the common bell relay contacts have an interrupted or continuous
closure when activated. If interrupted is chosen, the relay follows an internal Trunk Line
ring pattern of one second closed followed by three seconds open.
CONDITIONS
When the common bell is not used for night time ring, the common bell must be set to a
station group so that all stations in the group ring.
DEFAULT DATA
CONTINUOUS
ACTION
1) Press Transfer button and enter 204.
Display shows current setting:
2) Dial common bell number.
OR
Press Volume button to make selection of common
bell numbers and press Right Soft button to advance
cursor.
3) Dial 0 for continuous or 1 for interrupted operation.
OR
Use Volume button to scroll through options and press
Right Soft button to return to step 2.
4) Press Transfer button to save and exit.
OR
Press Speaker button to save and advance to next
MMC.
RELATED ITEMS
MMC 203
MMC 601
2-54
ASSIGN UA DEVICE
ASSIGN STATION GROUP
DISPLAY
[3801]COM. BELL
CONTINUOUS
[3801]COM. BELL
CONTINUOUS
[3802]COM. BELL
INTERRUPTED