5 Display Problems

Problem Area
Items to Inspect
If a display is not
Check whether the keyboard
functioning
illuminates 15 to 20 seconds after
pressing the power key
Inspect whether the LCD assembly's
flex film is properly connected to the
circuit board
Inspect each half of the LCD to
circuit board connection
If the issue has not been resolved
If the issue is still not resolved
1210-5425 Rev1
©
Company Internal
Sony Ericsson Mobile Communications AB
Repair Action
If the keyboard does not illuminate,
refer to the "Power Problems" section
If improperly connected - Reestablish
proper connection
If dirty or oxidized – Clean both
halves of the connection
If the portion of the connector on the
LCD is damaged - Replace the LCD
If the portion of the connector on the
circuit board is damaged – Escalate
to an electrical repair level
Replace the LCD if it has not been
replaced
Escalate to an electrical repair level