5 Initial value of peeling position

If the peeler function is selected when the power is turned on or the resetting is
performed, the media will automatically feed from the reference point to the peeling
position (by initial value of feeding amount), regardless of printer emulation.
To finely adjust the peeling position, transmit the command STX f or STX Kf from
the host computer to the printer. In this case, each command initial value being set
designates the zero (0) of peeling position, and the peeling position shifts front or
back by the parameter of each command. (For details, see the separate Command
Reference.)
<Each command initial value>
Emulation DM4 : 68.6 mm (2.70 in)
Emulation DMI : 12.7 mm (0.50 in)
Emulation DPP : 37.1 mm (1.46 in)
<Example of making fine adjustments>
STX f (nnn)
When the emulation is set to DM4, the peeling position shifts from zero (0) to
frontward position by 0.01 inch. In this case, the command is STX f (271).
The distance between the peeler sensor or platen center and the peeling position is
shown below.
Middle point
between labels
Peeling plate
Note: The measurements shown here are examples.
35.4 mm (1.39 in)
10.76 mm
(0.42 in)
Center of platen
I – 8
24.64 mm (0.97 in)
Label
Liner
Sensor position