6. Start generator as described in the section Starting the Engine, then
place shelter over generator. Keep at least 1.5m (5 ft.) clearance on all
sides of generator including overhead with shelter in place.
WARNING Exhaust heat/gases could ignite combustibles, structures
or damage fuel tank causing a fire, resulting in death or
serious injury.
Contact with muffler area could cause burns resulting in
serious injury.
• DO NOT touch hot parts and AVOID hot exhaust gases.
• Allow equipment to cool before touching.
• Keep at least 1.5 m (5 ft.) of clearance on all sides of generator including
overhead.
• Remove shelter when temperatures are above 4°C [40°F].
7. Remove shelter when temperatures are above 4°C [40°F].
8. Turn engine OFF and let cool two (2) minutes before refueling. Let any
spilled fuel evaporate before starting engine.

Don't Overload Generator

Capacity
You must make sure your generator can supply enough rated (running) and surge
(starting) watts for the items you will power at the same time. Follow these simple
steps:
1. Select the items you will power at the same time.
2. Total the rated (running) watts of these items. This is the amount of
power your generator must produce to keep your items running. See
Wattage Reference Guide.
3. Estimate how many surge (starting) watts you will need. Surge wattage
is the short burst of power needed to start electric motor-driven tools or
appliances such as a circular saw or refrigerator. Because not all motors
start at the same time, total surge watts can be estimated by adding only
the item(s) with the highest additional surge watts to the total rated watts
from step 2.
Example:
Rated (Running)
Tool or Appliance
Window AC - 10,000 BTU
Deep Freezer
Television
Security System
Light (100 Watts)
2480 Total Running
Total Rated (Running) Watts
Highest Additional Surge Watts
Total Generator Output Required
Power Management
To prolong the life of your generator and attached devices, it is important to take
care when adding electrical loads to your generator. There should be nothing
connected to the generator outlets before starting its engine. The correct and
safe way to manage generator power is to sequentially add loads as follows:
1. With nothing connected to the generator, start the engine as described
in this manual.
2. Plug in and turn on the first load, preferably the largest load you have.
3. Permit the generator output to stabilize (engine runs smoothly and
attached device operates properly).
4. Plug in and turn on the next load.
5. Again, permit the generator to stabilize.
6. Repeat steps 4 and 5 for each additional load.
14
Additional Surge
Watts
(Starting) Watts
1200
1800
500
500
500
180
100
1800 Highest Surge
Watts
Watts
= 2480
= 1800
= 4280
NEVER add more loads than the generator capacity. Take special care to
consider surge loads in generator capacity, as described above.
Wattage Reference Guide
Tool or Appliance
Essentials
Light Bulb - 100 watt
Deep Freezer
Sump Pump
Refrigerator/Freezer - 18 cf
Water Well Pump - 1/3 hp
Heating/Cooling
Window AC - 10,000 BTU
Window Fan
Furnace Fan Blower - 1/2 hp
Kitchen
Microwave Oven - 1000 Watt
Coffee Maker
Electric Stove - Single Element
Family Room
DVD/CD Player
VCR
Stereo Receiver
Color Television - 27 in
Personal Computer w/17 in monitor
Other
Security System
AM/FM Clock Radio
Garage Door Opener - 1/2 hp
DIY/Job Site
Quartz Halogen Work Light
Airless Sprayer - 1/3 hp
Reciprocating Saw
Electric Drill - 1/2 hp
Circular Saw - 7-1/4 in
* Wattages listed are approximate only. Check tool or appliance for actual wattage.
Rated*
Additional
(Running)
Surge (Starting)
Watts
Watts
100
500
500
800
1200
800
1600
1000
2000
1200
1800
300
600
800
1300
1000
1500
1500
100
100
450
500
800
180
300
480
520
1000
600
1200
960
960
1000
1000
1500
1500
BRIGGSandSTRATTON.COM