Description: This test checks the ROM (U206) and the data bus to the output of the Data Latches (U217) in the system
microcomputer.
Test Setup: Use the test setup described in paragraph 4-23. Connect jumper pack W202 in the NOP and set up the
signature analyzer as shown below.
Signature Analyzer
Input
START
STOP
CLOCK
GND
Measurements: Use the data probe to take signatures for each circuit at the output pins listed below. These signatures
apply to the firmware revsions listed. Refer to Appendix A for previous versions.
Date code -->
Revision #-->
Circuit
+5
ROM U206
Data Bus Lines
System Microcomputer
Data Latches
U217
Table 4-7. GPIB Board S.A. Test No. 2
Edge
Setting
Output
P201-1
U206-11
U206-12
U206-13
U206-15
U206-16
U206-17
U206-18
U206-19
U217-2
U217-5
U217-6
U217-9
U217-12
U217-15
U217-16
U217-19
4-21
P201 PIN
Connection
9
10
14
4
2629
2839
A.00.02
A.00.03
Signatures
0001
0001
AH2C
UF2F
13CC
9650
PUCC
4134
C2A3
164A
HU49
3449
PF79
A11F
3856
H930
AHU7
A791
H694
UP17
09HF
4C29
77HF
A09C
H950
8C24
6UA5
9A25
U63H
508U
1F2A
6F99
H6UA
53F9