Danfoss ECtemp Next Plus
It would also be possible to use only one temperature
sensor. However, this option is not recommendable as this
cause an increased risk of overheating of the floor.
Extending maximum floor temperature and Setting into
room only mode – See point 4.9 and 4.10.
IMPORTANT: When the thermostat is used to control a
floor heating element in connection with a wooden floor or
similar material, always use a floor sensor and never set the
maximum floor temperature to more than 35 ° C.
Thermal
resistance
[m
K/W]
2
0.05
0.10
0.13
< 0.17
0.18
Installation Guide
Examples of
Flooring
8 mm HDF
based lami-
nate
14 mm beech
parquet
22 mm solid
oak plank
Max. carpet
thickness suit-
able for floor
heating
22 mm solid
for planks
Details
>800 kg/m
3
650 - 800
kg/m
3
>800 kg/m
3
acc. to EN
1307
450 - 650
kg/m
3
Approximate
setting for
25˚C floor
temperature
28˚C
31˚C
32˚C
34˚C
35˚C