C13/C33 Concentric Systems - A.O. Smith Innovo 12-160 Installation, Service & Maintenance Manual

Condensing high-efficiency water heater
Table of Contents

Advertisement

8.7.1
44

C13/C33 concentric systems

Use a wall terminal set or a roof terminal set to install a C13 or a C33 concentric venting
system.
Description Concentric
Venting material
Manufacture venting material
Construction
Material flue gas outlet
Material air inlet
Diameter flue gas outlet
Diameter air inlet
Description parts
Wall terminal set
A wall terminal (1), a 500 mm
concentric pipe and a 90° bend
Wall terminal
Roof terminal set
A roof terminal (2), a 1000 mm
concentric pipe and a roof plate
Roof terminal
Concentric pipe 250 mm
Concentric pipe 500 mm
Concentric pipe 1000 mm
Concentric pipe 1500 mm
Concentric pipe 2000 mm
Concentric pipe telescopic
Concentric pipe to cut
Concentric bend 45°
Concentric bend 90°
1 - supplied with wall flange and clamping ring
2 - supplied with clamping ring
3 - use this part to connect the air inlet and flue gas outlet to the water heater
Venting material
PP
Muelink & Grol
Concentric
PP - Temp. Class T120 Thick walled
Thin walled galvanized
steel
+0,6
80
/
mm
-0,6
+0,5
124
/
mm
-1
(Dn 125)
A.O. Smith Part
number
0310759
0310757
0310755
0310753
0310740
0310741
0310742
-
0310743
0310744
(3)
0310745
0310734
0310735
Installation, Maintenance and Service part
Venting material
Alu
Muelink & Grol
Concentric
aluminum
Thin walled galvanized
steel
+0,3
80
/
mm
-0,7
+0,5
124
/
mm
-1
(Dn 125)
A.O. Smith Part
number
0302515
0302516
0305042
0304983
-
0302510
0311448
0311449
-
-
-
0302514
0302513

Hide quick links: