Generating SNMP traps for system events
60
# clia setlanconfig 1 destination_type 2 0 0 0
3 Set the destination IP and MAC address, which is the IP and MAC address of the
SNMP server. The SNMP server can be on a different subnet.
# clia setlanconfig 1 destination_address 172.20.120.11
00:1A:A0:2F:BC:C6
4 Set the community name used in PET traps. This can be any community name, the
default is public.
# clia setlanconfig 1 community "<community_name>"
To configure the PEF event filter table
1 Enable PEF and enter a PEF control flag:
# clia setpefconfig control f
This command sets an 8-bit value, entered in hexadecimal and treated as a bit mask,
that represents control flags for PEF. The control value f enables PEF, enable the
generation of event messages for PEF actions, enables startup delays and enables
alert startup delays.
2 Enable alert actions:
# clia setpefconfig action_control 1
An 8-bit value entered in hexadecimal and treated as a bit mask. Setting
action_control to 1 enables alert actions.
3 Delay PEF and delay alerts for 60 seconds after the system powers up:
# clia setpefconfig startup_delay 60
# clia setpefconfig alert_startup_delay 60
4 Add event filter entries. The syntax of the command is:
# clia setpefconfig event_filter <entry_number>
<flter_configuration> <filter_action> <alert_policy_number>
<severity> <IPMB_address> <channel> <sensor_type>
<sensor_number> <event_type> <event_offset> 0 0 0 0 0 0 0 0 0
Each even filter command adds or edits and event filter table entry. Each entry consists
of a <entry_number> and a <filter_action> followed by 19 numeric values, in
hexadecimal, encoded according to the definition in table 15-2 of the IPMI specification
version 1.5 (http://download.intel.com/design/servers/ipmi/IPMIv1_5rev1_1.pdf).
<entry_number> is the filter entry number. Each entry must have a different number.
Adding a second entry with the same number overwrites the first entry with that
number.
<filter_configuration>. In this example the filter configuration is ways set to 80
to enable the filter.
<filter_action>. In this example the filter action is ways set to 1 to set the action
to alert.
<alert_policy_number>. In this example the alert policy number is 5.
<severity>. In this example the severity is 02 which means information level
messages and higher can trigger traps. Normally you would set severity to 08 for non-
critical conditions, 10 for critical conditions, or 20 for non-recoverable conditions to limit
the number of traps sent.
<IPMB_address> is the IPMB address of the FRU for which the alert is generated.
See
"IPMB addresses, logical and physical slot numbers, and FRU ids" on page
<channel> is the channel to match. FF means any channel.
Using the shelf manager CLI
30.
FortiGate-5060 Chassis Guide
01-400-129494-20110912
http://docs.fortinet.com/
Feedback

Advertisement

Table of Contents
loading

Table of Contents