Fru; Display Information For All Frus - Fortinet FortiGate-5060 Chassis Manual

Hide thumbs Also See for FortiGate-5060:
Table of Contents

Advertisement

Using the shelf manager CLI

fru

Display information for all FRUs

FortiGate-5060 Chassis Guide
01-400-129494-20110912
http://docs.fortinet.com/
Feedback
clia fru [-v] [<IPMB_address> [id=<fru_device_id> |
type=<site_type>]] | [type=<site_type> [/<site_number>]]
This command displays information about a specific FRU. If <FRU_device_ID> is
omitted, the command shows information about all FRUs controlled by the IPM controller
at the specified address. If <IPMB_address> is also omitted, the command displays
information about all FRUs known to the shelf manager.
Enter the following command to display all of the FRUs at IPMB address 20 (fans, PEMs,
and so on):
# clia fru 20
Pigeon Point Shelf Manager Command Line Interpreter
20: FRU # 0
Entity: (0xf0, 0x1)
Hot Swap State: M4 (Active), Previous: M3 (Activation In
Process), Last State Change Cause: Normal State Change
(0x0)
Device ID String: "PPS BMC"
20: FRU # 1
Entity: (0xf2, 0x60)
Hot Swap State: M4 (Active), Previous: M3 (Activation In
Process), Last State Change Cause: Normal State Change
(0x0)
Device ID String: "Shelf EEPROM 1"
20: FRU # 2
Entity: (0xf2, 0x61)
Hot Swap State: M4 (Active), Previous: M3 (Activation In
Process), Last State Change Cause: Normal State Change
(0x0)
Device ID String: "Shelf EEPROM 2"
20: FRU # 3
Entity: (0x1e, 0x60)
Hot Swap State: M4 (Active), Previous: M3 (Activation In
Process), Last State Change Cause: Normal State Change
(0x0)
Device ID String: "FanTray1"
20: FRU # 4
Entity: (0x1e, 0x61)
Hot Swap State: M4 (Active), Previous: M3 (Activation In
Process), Last State Change Cause: Normal State Change
(0x0)
Device ID String: "FanTray2"
20: FRU # 5
Entity: (0x15, 0x60)
Hot Swap State: M4 (Active), Previous: M3 (Activation In
Process), Last State Change Cause: Normal State Change
(0x0)
fru