Fortinet FortiGate-5060 Chassis Manual page 13

Hide thumbs Also See for FortiGate-5060:
Table of Contents

Advertisement

FortiGate-5060 chassis
FortiGate-5060 Chassis Guide
01-400-129494-20110912
http://docs.fortinet.com/
Feedback
Table 3: FortiGate-5060 shelf alarm panel LEDs
LED
State
CRT
Off
(critical)
Red
Blinking
Red
MAJ (major) Off
Red
Blinking
Red
MIN (minor) Off
Amber
Blinking
Amber
USER3
Off
USER2
Amber
USER1
Blinking
Amber
Table 4: FortiGate-5060 shelf alarm panel connectors
Connector
Type
Speed
SERIAL 1
RJ-45
9600 bps,
8/N/1
SERIAL 2
RJ-45
9600 bps,
8/N/1
ALARM
micro
N/A
DB-15
male
Figure 5
shows the connections between the primary and secondary shelf managers and
the shelf alarm panel.
Description
Normal operation.
Indicates a critical alarm.
Alarm cutoff (ACO) activated by pressing the alarm LED reset button.
Normal operation.
Indicates a major alarm.
Alarm cutoff (ACO) activated by pressing the alarm LED reset button.
Normal operation.
Indicates a minor alarm.
Alarm cutoff (ACO) activated by pressing the alarm LED reset button.
Normal operation
Indicates a user-definable alarm.
Alarm cutoff (ACO) activated by pressing the alarm LED reset button.
Protocol
Description
RS-232
Serial connection to the primary shelf manager
serial
command line interface.
RS-232
Serial connection to the secondary shelf
serial
manager command line interface.
Telco
The external dry relay Telco alarm interface
Form-c
(48VDC) provides Telco form-c relay
connections for minor, major and critical power
faults. The cable required to connect to the
alarm interface is not supplied by Fortinet.
FortiGate-5060 shelf alarm panel
13