Clearance Between Needle And Hook (Adjustment Method No.2) - ELNA 1000 Sew 75 Service Manual

Table of Contents

Advertisement

CLEARANCE BETWEEN NEEDLE AND HOOK (ADJUSTMENT METHOD NO.2)

To check:
Use this adjustment method NO. 2 when method NO.1 cannot be used.
The clearance between the needle and shuttle race should be –0.05 to +0.10 mm.
Adjustment procedure:
1.
Set the pattern selector dial at "
2.
Remove the rear cover (See page 7).
3.
Loosen the setscrew (A) on the lower shaft bushing and slide the gear about 0.5 mm to the right to
create some slack between the gears.
4.
Lower the needle and loosen the two shuttle race setscrews (B).
Move the shuttle race unit axially either forward or backward to adjust the clearance between the
needle and the shuttle race in the range of –0.05 to +0.10 mm.
5.
Set the pattern select dial at "
needle and inner edges of the shuttle race spring at the left and right needle drops are equal.
If not, adjust by turning the shuttle race unit.
6.
Tighten the two shuttle race setscrews (B).
7.
Loosen the setscrew on the lower shaft bushing and slide the gear back to the original position
while adjusting the backlash.
8.
Tighten screw (A) firmly.
9.
Attach the rear cover.
NOTE: The rotary play of the tip of the shuttle driver should be less than 0.3 mm and the lower
shaft should turn smoothly.
After the adjustment, check the hook timing.
Shuttle race
setscrews (B) (2 pcs.)
MECHANICAL ADJUSTMENT
".
", turn the handwheel to check if the clearance between the
Lower shaft bushing (front)
Setscrew (A)
–0.05 to +0.10 mm
Clearance should be equal
14
Needle
Shuttle race spring

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents