Floor Protection - Drolet ECO-55 Installation Manual

Hide thumbs Also See for ECO-55:
Table of Contents

Advertisement

Available languages

Available languages

D
D
C
MINIMUM CLEARANCES
CANADA
C
3" (76 mm)
D
Note 1
RECOMMENDED CLEARANCES FOR
MAINTENANCE
CANADA
C
12" (305 mm)
D
Note 1
Note 1 : Refer to the exhaust venting system manufacturer's
instructions for clearances to combustible materials.

3.2 FLOOR PROTECTION

Page 8
C
USA
3" (76 mm)
Note 1
USA
12" (305 mm)
Note 1
FLOOR PROTECTION
CANADA**
E
6" (152 mm)
From door opening
F
6" (152 mm)
From door opening
CAUTION
THE
STOVE
MUST
A
CONTINUOUS
NONCOMBUSTIBLE
CERAMIC TILE*, CEMENT BOARD, BRICK,
MILLBOARD OR EQUIVALENT, OR ANY OTHER
APPROVED OR LISTED MATERIAL SUITED
FOR FLOOR PROTECTION.
*Any type of tile will require a continuous non combustible sheet
beneath to prevent the possibility of embers falling through to the
combustible floor if cracks or separation should occur in the fini-
shed surface, this would include floor protection for built-in raised
hearths. Check local codes for approved alternatives.
**You may reduce the floor protection requirements to the values
shown in the previous table ONLY if the following actions are
respected: Allow for the appliance to shut-down and fire to
be extinguished. Once completely cool and all blowers have
stopped you may proceed with opening the firebox or ash door.
Otherwise, see CSA B365.
INSTALLATION MANUAL ECO-55/ECO-55ST
USA
6" (152 mm)
From door opening
6" (152 mm)
From door opening
BE
PLACED
(GROUTED
JOINTS)
MATERIAL
SUCH
ON
AS