1
2
► 1. Intermittent nailing 2. Continuous nailing
3. Change lever 4. Trigger lock
CAUTION:
Operating the tool without nails shortens the life
of the tool and should be avoided.

Air exhaust

► 1. Exhaust cover
Air exhaust direction can be changed easily by rotating
the exhaust cover. Change it when necessary.
Jammed nailer
CAUTION:
Always lock the trigger, disconnect the hose
and remove the nails from the magazine before
cleaning a jam.
When the nailer becomes jammed, do as follows:
Open the door and magazine cap and remove the nail
coil. Insert a small rod or the like into the ejection port
and tap it with a hammer to drive out the nail jamming
from the ejection port. Reset the nail coil and close the
magazine cap and door.
3
4
1
7 ENGLISH
► 1. Small rod 2. Ejection port
Hook
1
► 1. Hook
The hook is convenient for hanging the tool temporarily.
This hook can be installed on either side of the tool.
CAUTION:
Always lock the trigger and disconnect the hose
when hanging the tool using the hook.
Always tighten the hook securing bolt firmly.
Loose bolt may cause air leakage from the tool.
Never hang the tool on a waist belt or like.
Dangerous accidental firing may result.
1
2

Advertisement