Table 7-1 Micromaster 430 Performance Ratings - Siemens MICROMASTER 430 Operating Instructions Manual

3ac-frequency inverter
Hide thumbs Also See for MICROMASTER 430:
Table of Contents

Advertisement

MICROMASTER 430 specifications
Table 7-1
MICROMASTER 430 Performance Ratings
Feature
Mains Operating Voltage
& Power Ranges
Input Frequency
Output frequency
Power Factor
Inverter Efficiency
Overload Capability for
variable torque (VT)
Inrush Current
Power-ON-OFF cycle time
Control Method
Pulse Frequency
Fixed Frequencies
Skip Frequencies
Setpoint Resolution
Digital Inputs
Analog Input 1
Analog Input 2
Relay Outputs
Analogue Output
Serial Interface
Electromagnetic Compatibility
Braking
Protection Level
Temperature range (VT)
Storage Temperature
80
Specification
VT
3 AC 380 to 480 V ± 10 %
47 to 63 Hz
0 Hz to 650 Hz
≥ 0.7
Frame Sizes C to F:
Frame Sizes FX and GX:
Frame Sizes C to F:
Frame Sizes FX and GX: 1.1 x Nominal output current
Less than rated input current
Frame Sizes C to E:
Frame Size F:
Frame Sizes FX and GX: every 300 s
Linear V/f control, Linear V/f control with FCC, Parabolic V/f control, Multi-point
V/f control, V/f control for textile applications, V/f control with FCC for textile
applications, V/f control with independent voltage setpoint
Frame Sizes C to F:
Frame Sizes FX and GX:
15, programmable
4, programmable
0.01 Hz Digital, 0.01 Hz Serial, 10 bit Analogue
(motor potentiometer 0.1 Hz [0.1% (in PID mode)])
6, programmable (isolated), switchable active high / active low (PNP/NPN)
0 - 10 V, 0 - 20 mA and –10 V to +10 V
0 - 10 V and 0 - 20 mA
3, programmable 30 V DC / 5 A (resistive), 250 V AC 2 A (inductive)
2, programmable (0 to 20 mA)
RS-485, optional RS-232
Frame Sizes C to F:
Frame Sizes FX and GX: With EMI filter (available as an option) the limiting
DC braking, Compound braking
IP20
Frame Sizes C to F:
Frame Sizes FX and GX: 0 °C to +40 °C (32 °F to 104 °F), to 55 °C (131 °F)
Power reduction see Figure 2-2
-40 °C to +70 °C (40 °F to 158 °F)
http://nicontrols.com
7.50 kW – 90.0 kW
(10.0 hp – 120 hp)
96 % to 97 %
97 % to 98 %
1.1 x Nominal output current
(i.e. 110 % overload) for 60 s every 300 s and
1.4 x Nominal output current
(i.e 140 % overload) for 3 s every 300 s
(i.e. 110% overload) for 59 s every 300 s and
1.5 x Nominal output current
(i.e 150% overload) for 1 s every 300s
every 30 s
every 150 s
2 kHz to 8 kHz (2 kHz steps)
2 kHz to 8 kHz (2 kHz steps)
(Standard 2 kHz (VT),
power reduction see Table
7-3)
Optional EMC filters to EN 55011 Class A or B,
also Internal Class A filters available
values of the EN 55011, Class A are fulfilled for
conducted emission (line commutating choke
required).
-10 °C to +40 °C (14 °F to 104 °F)
MICROMASTER 430
Issue 10/06
Operating Instructions
6SE6400-5AE00-0BP0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents