Test Mode - Roland Juno-GJ Service Notes

128 voice expandable synthesizer with audio/midi song recorder
Table of Contents

Advertisement

Apr. 2006
7.
Insert the memory card to the JUNO-G which power is turned off.
8.
Turn on the power of the JUNO-G.
Updating starts automatically.
When message "- Completed!" appears in the screen, updating is
completed.
9.
Remove the memory card and turn off and on the power.
Work after Updating
1.
After System Update, execute Checking Version Number (p. 15) and
Test Mode (p. 17).
2.
Restore the data which were saved in User Memory by step 1 in Update
Procedure (p. 16). Refer to Data Load (User Restore) (p. 16).
If You Made a Mistake on
Updating
• Turn off the power of the JUNO-G and operate from the beginning again.
• If the updating still cannot be successful, exchange the MAIN Board.

Test Mode

All data in User Area will be lost after executing Test Mode. If the data which
should be saved are left in the JUNO-G, save them in memory card by User
Backup function. Refer to Data Save (User Backup) (p. 15).
Procedure of JUNO-G Test Mode is different between ver. 1.01 or before and
ver. 1.02 or later. This service notes explains procedure for ver. 1.02 or later.
Check the version (Checking Version Number (p. 15)), and if the version is
1.01 or before, then update to ver. 1.02 or later before executing Test Mode.
(System Update (p. 16))
Required Items
• JUNO-G
• Memory Card (equal or less than 1GB)
• Memory (DIMM: 128--512 MB)
• Wave Expansion Board: SRX series
• Expression Pedal (e. g. EV-5)
• Headphones
• Noise Meter
• PC (with USB connector, OS: Windows Me/2000/XP)
• USB Cable x 1
• MIDI Cable x 1
• Audio Cable x 4 or 6
• Monitor Speaker
• Oscillator
• Oscilloscope
Preparation of Test
1.
Turn off the power of JUNO-G.
2.
Remove the cover on the bottom and set the memory (DIMM) and the
SRX.
3.
Turn on the power of the JUNO-G and execute the Factory Reset.
(Factory Reset (p. 16))
4.
After completing the Factory Reset, turn off and on the power of the
JUNO-G.
5.
Now, boot up the PC for the test of 14. USB (p. 21).
Entering Test Mode
1.
Press [MENU] in EDIT.
2.
Press [
] to select 2. System, and press [ENTER].
System Menu appears.
fig.00
3.
Press [F6 (INFORMATION)].
SYSTEM INFO appears.
fig.01
4.
Press [SHIFT], [F4 (WORLD)], [F5 (BRASS)] and [ENTER] one by one in
this order.
Test Mode starts.
* If you make a mistake in the order, turn off and on the power of the JUNO-G and
retry from the step 1.
Exiting Test Mode
Turn off the power of the JUNO-G.