6.3 Error Messages
If the Display reacts differently from what is indicated in the manual, (we call this an error message). The most
likely reason for this is that you have executed an incorrect operation. The following shows JX-10 error messages
and explains how to correct them.
MEMORY PROTECTED

INSERT CARTRIDGE

SELECT NO. 1-50
Note: The JX8P Cartridge is no longer supported. As such, the old error messages relating to this cartridge have
now been removed.
6.4 JX-10 RESET
To reset JX-10 MIDI, Arpeggiator and Controls to their default values (Patches and Tones will remain untouched)
press:
WRITE +  LOWER + UPPER when powering up the JX-10.
B e a r i n m i n d : T h e J X - 1 0 w i l l i s s u e n o i n d i c a t i o n t h a t t h e r e s e t h a s b e e n d o n e !
!! If the keyboard doesn't respond after the reset, ensure that LOCAL is set to ON !!
Also, there is NO JX-10 factory reset procedure to re-load all patches and tones to original factory settings!
Upon issuing a RESET, this data will not be changed – it remains as it was before the RESET. If you wish patches
and tones to be returned to original factory settings then you must either copy the data back to Internal memory
from a Cartridge or reload the data via an external software program and sysex.
NOTE: If the internal backup battery requires replacement, ALWAYS copy all settings to a Cartridge first as
all patches and settings will be erased at the moment the battery is removed.
MEMORY ERR
You have tried to execute a WRITE procedure without setting the
relevant Protect switch to the OFF position. When the Voice
Memory switch on the JX-10 is set to the INT position, the Protect
switch on the JX-10 should be set to OFF. When it is in the CART
position, the Protect Switch on the Cartridge should be set to the
OFF position.
When the Voice Memory Switch is set to the CART position, in other
words, when the JX-10 is in Cartridge mode, this error message
may be seen if the cartridge is not securely connected (or missing).
Remove the cartridge (or insert it) then securely connect it in the
correct direction (with the Protect switch side facing upwards).
This error message is shown when you have tried to write the edited
Tone to a Tone Number other than 1-50. Tone numbers from 51-
100 are in ROM (Read-Only memory) and therefore cannot be
rewritten.
When this is shown several times, the JX-10 is in trouble. You will
need to have it repaired!