Bosch amax 2100 Operation Manual page 22

Hide thumbs Also See for amax 2100:
Table of Contents

Advertisement

22
en | Arming and disarming areas
Master keypad arming
With a master keypad, either all areas or a single area can be
armed in AWAY mode.
Arming all areas
4
P
Arming all areas (quick arm)
4
P
Arming a single area (direct AWAY arm)
Arming a single area with a master keypad is only possible for
users with the permission level master 1 or master 2.
4
P
4
To enable/disable this function contact your installer.
Key switch arming
Users can use a key switch to arm an area.
4
P
To enable/disable this function contact your installer.
RADION RF keyfob arming
Users can use a RADION RF four button keyfob to arm an area
via the third button.
4
2017.04 | 07 | F.01U.295.569
Enter your code, press [0] [0] and [*].
The system beeps twice, the STAY indicator flashes slowly
and exit time starts. After the exit time, the STAY indicator
is lit and all areas are displayed as armed.
Press and hold [*] until the system beeps twice.
The system beeps twice, the STAY indicator flashes slowly
and exit time starts. After the exit time, the STAY indicator
is lit and all areas are displayed as armed.
Enter your code, press the 2-digit area number of the area
to be armed and press [*].
The STAY indicator flashes slowly and exit time starts. After
the exit time, the STAY indicator is lit and the selected area
is displayed as armed.
Repeat if you want to arm multiple areas.
Activate the key switch.
The STAY indicator flashes slowly and exit time starts. After
exit time, the STAY indicator is lit.
Press the third button of the RADION RF four button
keyfob.