Auto White Balance Adjustment - Sony DCR-PC101E Service Manual

Digital video camera recorder
Hide thumbs Also See for DCR-PC101E:
Table of Contents

Advertisement

DCR-PC101/PC101E

13. Auto White Balance Adjustment

Adjust to the proper auto white balance output data.
If it is not correct, auto white balance and color reproducibility
will be poor.
Subject
Filter
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified value
Note 1: Perform "AWB & LV Standard Data Input" before this
adjustment.
Note 2: "Auto White Balance Adjustment" is available only once
after the power is turned on. Turn the power off, then on
again if the adjustment is retried.
Note 3: Check that the data of page: 0, address: 10 is "00".
Note 4: The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1 : XX : XX
Switch setting
1) POWER .................................................................. CAMERA
2) NIGHT SHOT .................................................................. OFF
3) DIGITAL ZOOM (Menu setting) .................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
RadarW
RadarW
RadarW
RadarW
RadarW
Clear chart
(Color reproduction adjustment
frame)
Filter C14 for color temperature
correction
Displayed data of page: 1 (Note 4)
Adjusting remote commander
F
34, 35, 44 to 47
R ratio: 2B90 to 2C90
B ratio: 59D0 to 5AD0
Displayed data
Adjusting method:
Order Page Address Data
1
2
0
01
3
F
44
4
F
45
5
F
46
6
F
47
7
6
13
8
6
10
9
6
01
10
11
6
01
12
6
02
13
6
01
14
0
03
15
1
16
0
03
17
1
Note 5: The adjustment data will be automatically input to page:
F, address: 34, 35, 44 to 47.
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
2
6
10
3
6
13
4
0
03
5
0
01
6
5-30
Procedure
Place the C14 filter on the
lens.
01
2C
Press PAUSE button.
10
Press PAUSE button.
5A
Press PAUSE button.
50
Press PAUSE button.
80
08
83
Press PAUSE button.
Wait for 2 seconds.
81
Press PAUSE button. (Note 5)
Check the data changes to
"01".
3F
Press PAUSE button.
04
Check that the displayed data
(Note 4) satisfied the R ratio
specified value.
05
Check that the displayed data
(Note 4) satisfied the B ratio
specified value.
Procedure
00
Press PAUSE button.
00
00
00
00
Remove the C14 filter on the
lens.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dcr-pc101

Table of Contents