Removing And Attaching The Terminal Cover - YASKAWA Varispeed L7 Instruction Manual

Current vector controlled inverter cimr-l7c series
Hide thumbs Also See for Varispeed L7:
Table of Contents

Advertisement

Removing and Attaching the Terminal Cover

Remove the terminal cover to wire cables to the control circuit and main circuit terminals.
Removing the Terminal Cover
Inverters of 18.5 kW or Less
Loosen the screw at the bottom of the terminal cover, press in on the sides of the terminal cover in the direc-
tions of arrows 1, and then lift up on the terminal in the direction of arrow 2.
Fig 1.11 Removing the Terminal Cover (Model CIMR-L7C43P7 Shown Above)
Inverters of 22 kW or More
Loosen the screws on the left and right at the top of the terminal cover, pull out the terminal cover in the direc-
tion of arrow 1 and then lift up on the terminal in the direction of arrow 2.
Fig 1.12 Removing the Terminal Cover (Model CIMR-L7C4022 Shown Above)
Attaching the Terminal Cover
When wiring the terminal block has been completed, attach the terminal cover by reversing the removal proce-
dure.
For Inverters with an output of 18.5 kW or less, insert the tab on the top of the terminal cover into the groove
on the Inverter and press in on the bottom of the terminal cover until it clicks into place.
1
2
1
2
http://nicontrols.com
Removing and Attaching the Terminal Cover
1
1
11
1-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents