SETTINGS OF CAMERA CONTROL AND STATUS REGISTER

This chapter describes CSR addresses using the lower 32 bits of 64 bits. (CSR: Abbreviation of Control and Status Register)
The omitted upper 32 bits are ∗∗∗∗FFFFh. (∗∗∗∗ changes according to the connection of the IEEE1394 Serial Bus.)
Read/Write of the CSR is executed in units of Quadlet (4 bytes). The CSR address is the address of the leading byte of the
Quadlet.
When describing the 32-bit command set for CSR in Hex, bit 0 is described as MSB (Most Significant Bit).
Example : 82012345h = 10000010 00000001 00100011 01000101b
= = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =
CSR F0F00000h
Camera Initialize Register (Write Only)
Executes the same operations as when Factory Setup was selected in Current Memory Channel of CSR F0F00624h.
Command: 80000000h
Resets the CSR F0F00800h – F0F0088Ch functions to factory settings.
At this time, return the CSR F0F00624h Current Mem. channel also to "0".
NOTE
: As serial No. 100101 to 100700 (DFW-V500), 100101 to 100900 (DFW-VL500) cameras do not
have this function, select Factory Setup in the CSR F0F00624h Current Memory Channel.
= = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =
CSR F0F00600h to F0F00624h control isochronous image transmission, and load/save settings of the camera.
CSR F0F00600h
Current Frame Rate
Specify the Frame Rates 1 to 4. (Frame Rate 1 cannot be used for Mode0)
NOTE
: Set when CSR F0F00614h Iso_EN is OFF (STOP).
:
bit 0
Frame Rate
----------------------------------------------------
1 (3.75 fps)
2 (7.5 fps)
3 (15 fps)
4 (30 fps)
Command
20000000h
40000000h
60000000h
80000000h
:
bit 31