  • Page 2: Table Of Contents

    DFW-V500 DFW-VL500 Table of Contents OUTLINE ........................1 MAIN FEATURES ...................... 1 SYSTEM COMPONENTS ..................2 SPECIFICATIONS ...................... 3 CONNECTION ......................4 NAMES AND FUNCTIONS OF PARTS ..............5 DIMENSIONS ......................6 CCD PIXEL LOCATION .................... 7 SPECTRAL CHARACTERISTICS (TYPICAL VALUES) ........8 FUNCTIONS ........................
  • Page 3: Outline

    DFW-VL500 OUTLINE The DFW-V500/VL500 is a color digital video camera utilizing a 1/3-type PS IT CCD. The DFW-V500 is the C-mounted type while the DFW-VL500 is a 12× zoom lens mounted type. The IEEE1394-1995 digital interface realizes a transfer speed of 400M bps and outputs VGA (640 × 480)/YUV (4 : 2 : 2)/30 fps.
  • Page 4: System Components

    DFW-V500 DFW-VL500 SYSTEM COMPONENTS Video Camera Module Video Camera Module IEEE1394 Cable DFW-V500 DFW-VL500 (6-pin, 4.5 m) C-mount Lens (Option) • VCL-08YM • VCL-12YM Host Adapter Card (Option) • VCL-16Y-M DFWA-400 • VCL-25Y-M • VCL-50Y-M • J6 × 11 MACRO (Canon)
  • Page 5: Specifications

    : 60 (W) × 61 (H) × 118.5 (D) mm DFW-VL500 Mass DFW-V500 : Approx. 305 g DFW-VL500 : Approx. 335 g Accessories : IEEE1394 cable (1), Lens mount cap (1) ... DFW-V500 Lens cap (1) ... DFW-VL500, Clamp filter (2) External trigger connector (male) (1), Operating Instructions (1)
  • Page 6: Connection

    DFW-V500 DFW-VL500 CONNECTION DFW-V500 DFW-V500 DFWA-400 C-mount Lens IEEE1394 Cable Recommended Lens: Host Adapter Card VCL-08YM VCL-12YM Host Equipment (PC, etc.) VCL-16Y-M VCL-25Y-M VCL-50Y-M J6 × 11 MACRO (Canon) Display DFW-VL500 DFW-VL500 DFWA-400 Display IEEE1394 Cable Host Adapter Card Host Equipment (PC, etc.)
  • Page 7: Names And Functions Of Parts

    -VL500 Digital Interface Digital Interface TRIG IN TRIG IN q Lens mount (C-mount) (DFW-V500) i Pilot lamp w Built-in zoom lens (DFW-VL500) Lights green when the power is turned on, and orange in the e Flange back hole (DFW-V500) isochronous transmission (enabled) state.
  • Page 8: Dimensions

    DFW-V500 DFW-VL500 DIMENSIONS DFW-V500 1" -32UNC 116.7 DFW-V500 -V500 Digital Interface Digital Interface TRIG IN TRIG IN 16.1 1/4" -20UNC 4-M3 (Effective Depth 5) Unit: mm DFW-VL500 M37 P0.75 118.5 DFW-VL500 -VL500 Digital Interface Digital Interface TRIG IN TRIG IN 16.1...
  • Page 9: Ccd Pixel Location

    DFW-V500 DFW-VL500 CCD PIXEL LOCATION : 692 (H) × 504 (V) Total number of pixels Number of effective pixels: 659 (H) × 494 (V) Number of output pixels : 640 (H) × 480 (V) : 7.4 µm (H) × 7.4 µm (V)
  • Page 10: Spectral Characteristics (Typical Values)

    DFW-V500 DFW-VL500 SPECTRAL CHARACTERISTICS (TYPICAL VALUES) Wavelength [nm]...
  • Page 11: Functions

    FUNCTIONS The DFW-V500/VL500 differs from conventional analog cameras in that no video signals will be output by just supplying power. It will start operating when designated commands are written in the CSR (Control & Status Register) specified in the 1394-based Digital Camera Specification Ver.1.20.
  • Page 12 DFW-V500 DFW-VL500 FUNCTIONS Brightness The brightness of images can be controlled by changing the black level setting. Adjust the brightness if the appropriate gradation cannot be obtained due to the blurring of the black portions of the image. When maximum value of Y output data is 255...
  • Page 13 Color Temperature This function was originally intended for selecting the optical filter. However with the DFW-V500/VL500, the R-gain and B- gain are set to the appropriate White Balance when color temperatures 3,200 K and 5,600 K light sources are used.
  • Page 14 • Hue Y/R – Y/B – Y → R/G/B conversion The DFW-V500/VL500 outputs Y/R – Y/B – Y signals as digital image signals. The equations for converting these signals to R/G/B signals are as follows. R ≈ Y + (R – Y) G ≈...
  • Page 15: Settings Of Camera Control And Status Register

    At this time, return the CSR F0F00624h Current Mem. channel also to “0”. NOTE : As serial No. 100101 to 100700 (DFW-V500), 100101 to 100900 (DFW-VL500) cameras do not have this function, select Factory Setup in the CSR F0F00624h Current Memory Channel.
  • Page 16 : Set when CSR F0F00614h Iso_EN is OFF (STOP). CSR F0F00608h Current Video Format Specify the Video Format. As the DFW-V500/VL500 is only compatible with Format0, the command is always 00000000h. NOTE : Set when CSR F0F00614h Iso_EN is OFF (STOP).
  • Page 17 Before setting Execute, set the CSR F0F00620h Memory Save Channel. Memory Save requires about one second to execute. After setting, do not write other commands for one second. Serial No. 100101 to 100700 (DFW-V500), 100101 to 100900 (DFW-VL500) cameras memorize only the CSR F0F00800h to F0F0088Ch settings. CSR F0F0061Ch One Shot Perform the isochronous transmission of images for only one frame.
  • Page 18 DFW-V500 DFW-VL500 SETTINGS OF CAMERA CONTROL AND STATUS REGISTER CSR F0F00624h Current Memory Channel Read out the camera settings (ch1, ch2) memorized by the CSR F0F00618h Memory Save or the factory settings (Factory) from the memory, and set in the camera.
  • Page 19 DFW-V500 DFW-VL500 SETTINGS OF CAMERA CONTROL AND STATUS REGISTER CSR F0F0080Ch White Balance Adjust the red and blue gains to properly capture white subjects in color. Two types of automatic adjustment modes are available. NOTE If the CSR F0F00830h Trigger is set to ON or if the CSR F0F0081Ch Shutter setting is less than 800h, the Auto function cannot be used.
  • Page 20 DFW-V500 DFW-VL500 SETTINGS OF CAMERA CONTROL AND STATUS REGISTER CSR F0F00818h Gamma Set the gamma characteristics. 80h is the standard value. Gamma Command ---------------------------------------------------- 82000080h OFF (1) 82000081h OFF (2) 82000082h CSR F0F0081Ch Shutter Set the exposure time of the electronic shutter. Auto exposure (CCD Iris) can be also set.
  • Page 21 DFW-V500 DFW-VL500 SETTINGS OF CAMERA CONTROL AND STATUS REGISTER Setting values of shutter speed for DFW-V500/VL500 Exposure Time (sec.) Setting Value (Decimal) Setting Value (Hexadecimal) 1898 76AH 1988 7C4H 2018 7E2H 2033 7F1H 1/3.75 2040 7F8H 1/7.5 2044 7FCH 1/15...
  • Page 22 DFW-V500 DFW-VL500 SETTINGS OF CAMERA CONTROL AND STATUS REGISTER CSR F0F00820h Gain Adjust the gain of the video signal amplifier. Auto Gain Control can be also set. (1) Manual adjustment Command = 820000nnh nn: Adjust in the range of 00h (min) – 12h (max).
  • Page 23 DFW-V500 DFW-VL500 SETTINGS OF CAMERA CONTROL AND STATUS REGISTER CSR F0F00830h Trigger When inputting a negative polarity signal to the TRIG IN connector at the back of the camera, isochronous transmission of images for only one frame will be performed.
  • Page 24: Command Sending Procedure Until Images Are Displayed

    DFW-V500 DFW-VL500 COMMAND SENDING PROCEDURE UNTIL IMAGES ARE DISPLAYED Acquiring the camera control register base address Read out the Configuration ROM and acquire the base address of the camera control register. The base address of the Configuration ROM is FFFF F0000000H.
  • Page 25 DFW-V500 DFW-VL500 COMMAND SENDING PROCEDURE UNTIL IMAGES ARE DISPLAYED Acquiring the format/mode/frame rate a) Check available formats Refer to the Inquiry register for video format and check the available formats. Address Action Data F0F00100H Read 80000000H As bit 0 is set, it means that Format0 is available.
  • Page 26: Command Setting And Operation Timing

    DFW-VL500 COMMAND SETTING AND OPERATION TIMING The DFW-V500/VL500 operates synchronously with 33.33 ms cycle internal pulses called VD. VDs are reference signals inside the camera and cannot be observed from outside the camera. Even if commands are set to the CSR of the camera, it does not mean that they become effective the instant they have been written.
  • Page 27 DFW-V500 DFW-VL500 COMMAND SETTING AND OPERATION TIMING Isochronous Transmission Start/Stop command and actual operation timing As shown in the following figure, it takes at least about 1 V for the actual isochronous transmission of image data to start or stop after the Isochronous Start/Stop command (CSR F0F00614h: ISO_EN) has been set to the CSR of the camera. (VDs are the reference signals inside the camera and cannot be observed from outside the camera.)
  • Page 28 DFW-V500 DFW-VL500 COMMAND SETTING AND OPERATION TIMING If Shutter (CSR F0F0081Ch) is set to the extended exposing mode, command execution may be delayed for the exposure time at maximum in addition to the previous delay for Isochronous Start. Isochronous output is prepared...
  • Page 29 DFW-V500 DFW-VL500 COMMAND SETTING AND OPERATION TIMING If Shutter (CSR F0F0081Ch) is set to the extended exposing mode, command execution may also be delayed same as the previous command for Isochronous Stop. Isochronous output stop is prepared Isochronous output stop is made...
  • Page 30 DFW-V500 DFW-VL500 COMMAND SETTING AND OPERATION TIMING One Shot CMD and actual operation timing As shown in the following figure, it takes at least about 1 V for the actual isochronous transmission to start after the One Shot command (CSR F0F0061Ch) has been set to the CSR of the camera.
  • Page 31 DFW-V500 DFW-VL500 COMMAND SETTING AND OPERATION TIMING Do not set a new One Shot command until isochronous transmission of one frame image data ends after the One Shot command has been set. Isochronous output is prepared Set One Shot in this period...
  • Page 32 DFW-V500 DFW-VL500 COMMAND SETTING AND OPERATION TIMING Timing between external trigger signal and video signal output When the Trigger Mode (CSR F0F00830h) is set to ON, the camera will start exposure as shown in the following figure when it detects the external trigger signal.
  • Page 33 DFW-V500 DFW-VL500 COMMAND SETTING AND OPERATION TIMING Trigger Mode command and actual operation timing It takes at least about 1 V for external trigger signals to be received (Trigger Mode) after the Trigger ON command has been set to the CSR (F0F00830h) of the camera during the isochronous output of the moving image. (VDs are the reference signals inside the camera and cannot be observed from outside the camera.)
  • Page 34 DFW-V500 DFW-VL500 COMMAND SETTING AND OPERATION TIMING As shown in the following figure, it takes at least about 1 V for the normal transmission of moving images to start after the Trigger OFF command has been set to the CSR (F0F00830h) of the camera. (VDs are the reference signals inside the camera and cannot be observed from outside the camera.)
  • Page 35: Shutter

    DFW-V500 DFW-VL500 SHUTTER When exposure time is 1 frame or shorter VDs are generated continuously inside the camera, and the video signals synchronize with them and are output by isochronous transmission. (VDs are the reference signals inside the camera and cannot be observed from outside the camera.) If a frame rate lower than 30 frame/s is selected at CSR F0F00600h Current Frame Rate, the image data output at the actual 30 frame/s will be interpolated in unit frame and transmitted at the designated frame rate.
  • Page 36 DFW-V500 DFW-VL500 SHUTTER The timing at which the video signal is output by isochronous transmission is as follows. Because the packet serving as the reference of the timing above 1394 bus and camera VD are asynchronous and the camera cannot dominate the bus 100% when other equipments are connected to the 1394 bus, the following output timing will vary.
  • Page 37 DFW-V500 DFW-VL500 SHUTTER When exposure time is over 1 frame Even if the exposure time over 1 frame (1/30 sec) is set, the time (A period) to the output of the video signal from VD at the time exposure completes and the time required (B period) for isochronous transmitting video signal of one frame will be the same as the previous section.
  • Page 38: Host Adapter Card Dfwa-400

    DFW-V500 DFW-VL500 HOST ADAPTER CARD DFWA-400 The DFWA-400 host adapter card is an IEEE1394 serial bus interface card. You can install this card in the PCI bus slot in IBM PC/AT compatible computer. Features PCI interface Complies with PCI Short Card (5 V, 32-bit) standard Complies with PCI Local Bus Rev 2.1 standard...
  • Page 39 DFW-V500 DFW-VL500 HOST ADAPTER CARD DFWA-400 Specifications I/F standard : IEEE1394-1995 standard Chip set : PCI Lynx Number of ports Supply voltage : +5 V, +12 V Operating temperature : 10 to 35°C (no condensation) : 107 × 138 mm...
  • Page 40 DFW-V500 DFW-VL500 HOST ADAPTER CARD DFWA-400 Installing the Host Adapter Card NOTE : Before installing the host adapter card in the computer, be sure to install the setup disk software provided. Otherwise the computer may freeze when started. After starting the computer, insert the floppy disk provided into the floppy disk drive.
  • Page 41 The demonstration software can be used for both Windows 98 and Windows NT4.0. The demonstration software can operate only with the Sony IEEE1394 digital camera DFW and XCD series*. It will not operate with other Sony products such as the Digital Handycam.
  • Page 42 DFW-V500 DFW-VL500 HOST ADAPTER CARD DFWA-400 Setting up the driver <For Windows 98> Turn on the PC power without installing the DFWA-400 in the PC, and start Windows. Start \Setup98\Setup recorded in the FD. After ejecting the FD, quit Windows, and turn off the PC power.
  • Page 43 Sony reserves the right to change specifications of the products and discontinue products without notice.
  • Page 44 4-14-1, Asahi-cho, Atsugi-shi, Kanagawa-ken, 243-0014 Japan Tel: +81-46-230-5873 Fax: +81-46-230-6243 http://www.sony.com/videocameras Sony Electronics Inc. 1 Sony Drive, Park Ridge, NJ 07656 Tel: +1-800-686-7669 Canada Sony of Canada Ltd. 115 Gordon Baker Rd, Toronto, Ontario M2H 3R6 Tel: +1-416-499-1414 Fax: +1-416-497-1774 Europe http://www.pro.sony-europe.com/isp/...