OUTLINES AND DIMENSIONS

PUZ-A12NKA7
PUZ-A12NKA7-BS
404.5<15-15/16>
Air intake
Air intake
Air discharge
22.3 <29/32>
Handle for moving
154.5 <6-3/32>
310 <12-7/32>
Free space around the outdoor unit
(basic example)
Min.100mm
<3-15/16>
Min.500mm
<19-11/16>
2 sides should be open in
the right, left and rear side.
OCH636A
PUZ-A18NKA7
PUZ-A18NKA7-BS
drain hole
ø 42
Installation bolt pitch
500<19-11/16>
40 <1-19/32>
2-10×21
oval hole
(Foundation Bolt M10
<W 3/8>)
22 <7/8>
809 <31-7/8>
62 <2-15/32>
100mm<3-15/16> or more as long as
no obstacle is placed on the
rear and right-and-left sides
of the unit
Min.350mm
<13-25/32>
Min.100mm
<3-15/16>
PUY-A12NKA7
PUY-A12NKA7-BS
2-U Shaped notched holes
(Foundation Bolt M10<W 3/8>)
23.2<15/16>
Terminal connection
Left ... Power supply wiring
Right ... Indoor/Outdoor wiring
Earth terminal
Service panel
2- ø 22.2<7/8>
1/2 conduit hole
FOUNDATION BOLTS
Please secure the unit firmly
with 4 foundation (M10<W3/8>) bolts.
(Bolts, washers and nut must
be purchased locally).
<Foundation bolt height>
PIPING-WIRING DIRECTION
Piping and wiring connection can
be made from the rear direction only.
14
PUY-A18NKA7
PUY-A18NKA7-BS
Service panel
for charge plug
Connection for
liquid pipe
Connection for
gas pipe
Service port
185.5 <7-5/16>
FOUNDATION
Unit: mm<in>
FLARE  ø
6.35 (1/4F)
FLARE  12.7 (1/2F)
ø