Note
• Output order
When scan results and data are output by Ethernet, data is output first followed by the scan result (text string).
Example - Scan result: ABC
When
[Data output] - [Data 0]: 0 (judgment OK)
[Data output] - [Data 2]: 100 (cell recognition rate)
output is in the following order:
0 (field separator) 100 (record separator) ABC (record separator) CR
• Code conversion
The following character codes are converted before output:
Character code
Comma
Tab
Space
CR
LF
Outputting Data to an External Device Using No-protocol Communications
Setting the Data To Output Automatically
Refer to Setting the Data to Output via Ethernet.
Setting the Data Format
[In/Out] − [I/O setting] − [Ethernet]
1
Press [Output form].
2
Set the output format to ASCII or binary.
3
Set the data format.
• When Output Format Is ASCII
Set the parameters for integer digits, decimal digits, negative numbers, 0 suppression, the field separator,
and the record separator.
122
Outputting/Controlling with Ethernet
Before conversion
After conversion
&h2c
&h8540
&h09
&h8541
&h20
&h8542
&h00
&h8543
&h0A
&h8544