Preparation - Bosch HEI7052C Installation Instructions Manual

With european convection
Hide thumbs Also See for HEI7052C:
Table of Contents

Advertisement

Available languages

Available languages

preparation

parts provided:
• Anti-Tip Bracket
• 2 wood screws
• 2 anchorless concrete screws
• Foam Tape
• Terminal Lugs (For Use With Hard Wire
Installations)
note: not necessary for Canadian installations
tools and parts needed:
• 40 or 50 Amp Power Supply Cord Kit (depending
on local code)
note: Not necessary for Canadian installations
• Measuring Tape
• Phillips Head Screwdriver
• 1-1/4" Wrench
• Pencil
• T-20 Torx Screwdriver
• Screws (2) and Anchors (2) for Anti-Tip Bracket
(Style will vary depending on mounting surface)
• Level
• Drill and Drill Bit (3/16" masonry bit for
concrete screws)
• Soapy Water
• Safety Gloves and Goggles
• Tape (Optional)
• Cloth or Cardboard (Optional - to Protect Floor)
additional parts needed for
hard wire Installations
• Flexible Conduit
• Torque Wrench
note: Power Supply Cord Kit Not Necessary For Hard
Wire Installations
general Information
overall dimensions
dimension
inches
Height
36"
Width
29 ⁵⁄₁₆"
Depth
25 5/8"
level
For best results, cabinets, countertops walls and
floors in the installation location should be as level
and plumb as possible. Variance may cause damage
to countertops and floors during installation, could
jeopardize the seal around the cooktop and may
adversely affect cooking and baking performance.
centimeters
91.44 cm
74.55 cm
65.09 cm
tips:
Tape warming drawer shut to keep it from ope-
ning while installing the range.
During installation, place a portion of the box
or a piece of cloth under the range to protect
floors.
To make range lighter and easier to handle
remove door (see instructions in Use and Care
manual).
electrical requirements
Refer to data plate for more information. See "Pro-
duct Data Plate" on page 23 for data plate location.
We recommend that the range be installed with a
power cord set (not supplied). The electrical rating
of the power cord set must be 120/240 volt, 30 am-
peres minimum. The power cord set shall be marked
"For Use with Ranges." Always use a new power
cord.
note: In Canada, the range is shipped from the fac-
tory with the range cord already installed.
Ranges are dual rated for use on either 120/240 VAC
or 120/208 VAC. Check the data plate for the kW
rating. Reference the kW rating in the table below to
determine amperage requirements.
electrical specifications
Volts a.c.
hZ
rating KW circuit breaKer
120/240
60
120/240
60
120/208
60
120/208
60
Varies by location. Check local codes.
1
The electrical outlet must be located
in the shaded space.
7 1/2"
(190.5 mm)
4 1/2"
(114.3 mm)
(762 mm)
13
40 or 50 AMPS
13.8
40 or 50 AMPS
9.8
40 or 50 AMPS
10.4
40 or 50 AMPS
3 1/2"
(88.9 mm)
4 1/2"
21" (533.4 mm)
(114.3 mm)
30"
1
1
1
1
5