11

List of parameters

.02.03
1
105
110
116
117
3
382
387
4
452
5
521
538
6
605
606
607
609
615
618
623
Speed for seam start
Speed for seam end
Soft starting stitches
Speed for soft starting stitches
Analogue input switching threshold for the
thread monitor
Output Ax (motor operation) is active
ON = with the pedal 1D (motor running);
OFF = with the pedal 1 (lower presser foot)
"Lock-out" input
ON = yes
OFF = no (no function)
Needle position at sewing stop before seam
end
ON = needle position "2" (top)
OFF = needle position "1" (bottom)
Output timing Ax (thread tension release)
Actual speed on the display
ON = yes
OFF = no
Speed stage 1 (min.)
Speed stage 12 (max.)
Trimming speed 1
End detection by light barrier
ON = from light to dark;
OFF = from dark to light
Reverse rotation after seam end
ON = yes
OFF = no
Switch-on delay for reverse rotation [ms]
Input
B,C
300 - 1500
1000
B,C
300 - 1500
1000
B,C
0 - 30
B,C
30 - 1000
B,C
0 - 100
B,C
ON - OFF
B,C
ON - OFF
B,C
ON - OFF
B,C
10 - 50
B,C
ON - OFF
OFF
B,C
30 - 300
B,C
300 - 3500
2500
B,C
60 - 300
B,C
ON - OFF
B,C
ON -OFF
B,C
0 - 2000
0
400
15
ON
ON
ON
30
180
180
ON
ON
30
59