Closed with Code Change in Fabric OS v7.4.0

This section lists the defects with Critical, High and Medium Technical Severity closed with a code change as of
March 31, 2015 in Fabric OS v7.4.0.
Defect ID: DEFECT000417089
Technical Severity: Medium
Product: FOS
Reported In Release: FOS7.1.0
Symptom: Invalid VF numbers can be specified in TACACS+
Condition: If 0 is configured for the role list in tacacs/radius/ldap server configuration, userconfig --show will
show '0' also in the role list details.
Workaround: Avoid configuring the value '0' for role list
Defect ID: DEFECT000420903
Technical Severity: Medium
Product: FOS
Reported In Release: FOS7.0.0_pha
Symptom: Graphic for external management port is lit with no connection for 6547 switch.
Condition: When RJ45 cable is removed from the switch faceplate, Webtools still shows external management
port with solid green LED.
Defect ID: DEFECT000431369
Technical Severity: High
Product: FOS
Reported In Release: FOS7.0.2
Symptom: Mib browser displays ascii-hex of populated fcportflag value. For example it displays "30" for 0, "31"
for 1, where expected display is "0", "1".
Condition: This is seen only for the MIB display of fcportflag.
Defect ID: DEFECT000436921
Technical Severity: High
Product: FOS
Reported In Release: FOS6.3.1_dcb
Symptom: Console may hang, leading to switch Panic from unexpected termination of daemons from Out of
Memory condition.
Condition: This may be observed while performing supportsave or other CLI management operations
Defect ID: DEFECT000453829
Technical Severity: High
Product: FOS
Reported In Release: FOS7.2.0
Symptom: Traffic could be extra slow with BufOpMode enabled
Condition: For the FC8-32 and FC8-48 port blade, routing from an E-Port to an F-Port on the same ASIC
Workaround: slotpoweroff then slotpoweron.
Fabric OS 7.4.1a Release Notes v3.0
Probability: Medium
Technology: Security
Technology Area: Fabric Authentication
Probability: Medium
Technology: Management
Technology Area: Web Tools
Probability: Medium
Technology: Management
Technology Area: SNMPv2, SNMPv3 & MIBs
Probability: Low
Technology: System
Technology Area: CLI
Probability: High
Technology: Traffic Management
Technology Area: Routing