Open Defects in Fabric OS v7.4.0

This section lists the open defects with Critical, High and Medium Technical Severity as of March 31, 2015 in
Fabric OS v7.4.0
Defect ID: DEFECT000455926
Technical Severity: Medium
Product: FOS
Reported In Release: FOS7.2.0
Symptom: Devices outside of fail-over disabled TI zone will have portcam entries if there is an alternative path,
other than the TI zone, to reach the device in remote switch
Condition: Devices that are excluded from connectivity to each other in accordance with the TIZ configuration,
are visible to each other in the Name Server. Devices will get the details of the zoned devices and
PLOGIs sent to these devices will be dropped, sent to Non TI zoned devices
Defect ID: DEFECT000463170
Technical Severity: Medium
Product: FOS
Reported In Release: FOS7.2.0
Symptom: ipsecconfig command may hang the command line
Condition: ipsecconfig --disable command may hang and not work properly. Subsequent disable/re-enables may
fail.
Defect ID: DEFECT000470634
Technical Severity: High
Product: FOS
Reported In Release: FOS7.2.0
Symptom: A static and a learning flow cannot monitor the same traffic at two ports on the same chip.
Condition: A static and a learning flow created on same chip where the traffic on the static flow is a subflow for
the learning flow.
Defect ID: DEFECT000471762
Technical Severity: High
Product: FOS
Reported In Release: FOS7.2.0
Symptom: Two bi-directional flows monitoring a common subset of traffic do not monitor the frame and byte
parameters for one of the flows.
Condition: Two bi-directional (option -bidir) flows on the same chip monitoring a common subset of traffic and
with one of the device parameters (srcdev or dstdev) not specified.
Fabric OS 7.4.1a Release Notes v1.0
Probability: Low
Technology: Traffic Management
Technology Area: TIZ - Traffic Isolation Zoning
Probability: Low
Technology: Management
Technology Area: Ethernet Interface
Probability: Low
Technology: Monitoring/RAS
Technology Area: Flow Vision: Flow Monitor
Probability: Medium
Technology: Monitoring/RAS
Technology Area: Flow Vision: Flow Monitor