Troubleshooting

4.0 Troubleshooting
4.1
Information on failure display
and trouble-shooting
Refrigerators with an electronics system
(MES, AES) indicate the occurence of a mal-
function by the LED or display flashing.
If a malfunction occurs, the indicator LED
"Failure" (1) flashes simultaneously. In the
1
case of AES models an acoustic alarm
sounds.
1
1 = Indicator LED failure
2
2 = Operating mode display
3 = Temperature level display
3
4
4 = additonal Indicator LED failure RMD
5 = Operating mode display RMD
5
Display : LED (1) flashes +
1
MES
LED is flashing
LED is flashing
LED is flashing
All temperature setting
LEDs are flashing
LED + all tempe-
rature setting
LEDs are flashing
LED + all tempe-
rature setting
LEDs are flashing
AES
"230" is flashing
"12" is flashing
"GAS" is flashing
All temperature setting
LEDs are flashing
"HE1" is flashing
"HE2" is flashing
28
4.1.1

Status messages on the display

1
1
2
2
1
1
2
2
RMD 8xxx
1
1
Mode
Failure :
230V mode: "230V" not available or voltage too
low
12V mode: "12V" not available or voltage too low
GAS/Auto mode: Flame not ignited
Temperature sensor defective, refrigerator works
on mid temperature setting
230V - Heating element defective / or cooling unit
12V - Heating element defective / or cooling unit
3
3
Fig. 39
3
3
Fig. 40
4
4
5
5
Fig. 41