    Instruction CF-RC Remote Controller Index 1. Functional Overview ............4 1.1 Front .
  • Page 4: Functional Overview

     Screw and wall plug.  Transformer/power supply plug. Note: CF-RC Remote Controller has a self-explanatory menu structure. All settings are easily carried out with the up/down and left/right selectors in combination with the soft keys. When the display back light is out, the first touch of a button only activates this light.
  • Page 5: Activate Install Mode On Remote Controller

    Instruction CF-RC Remote Controller 2.3 Activate Install mode on Remote Controller (fig. 1) • When the batteries have been connected, follow the installation guide, beginning with the selection of language. • After the installation process, set time and date by using the up/down selector  and the left/right selector . Confirm settings with OK.
  • Page 6: Mounting

    Instruction CF-RC Remote Controller 4. Mounting 4.1 Remote Controller has been installed (fig. 2) When Remote Controller has been installed to Master Controller (see chapter 2), it can be mounted on the wall by means of the back plate/docking station . This makes it possi- ble to connect Remote Controller to a 230 V power supply with the included transformer/ power supply plug .
  • Page 7: Options

    Instruction CF-RC Remote Controller 5.1.2 Options Menu  Rooms  Options: From the Rooms menu, select Options to get access to the following room options: • Set temperature: Set and lock set temperature for the room thermostat. Locking pre- vents adjustment of set temperature on the room thermostat.
  • Page 8: Setback Program

    Instruction CF-RC Remote Controller 5.2.2 Setback program Menu  Program  Setback program  Program setback: From the Program menu, se- lect Setback program  Program setback to divide rooms in (up to) six zones with (up to) three different programs for reduced room temperature at different times during the day.
  • Page 9 Instruction CF-RC Remote Controller Select time for the setback program by defining the time periods with normal room tem- perature, indicated by the black bars above the time line (the periods outside the black bars are the setback periods with reduced room temperature).
  • Page 10: Setup

    Instruction CF-RC Remote Controller 5.3 Setup Menu  Setup: From the start-up screen, activate the Setup menu to get access to a variety of information and setting possibilities for Remote Controller as well as the entire system. As some of the setting possibilities in the Setup menu can affect the con-...
  • Page 11: Alarms

    Instruction CF-RC Remote Controller 5.4 Alarms If an error occurs in the CF2 system, it is indicated by Master Controller and directly on the Remote Controller display: An alarm has occurred. Press key to acknowledge. When the alarm is acknowledged with OK, the Master Controller buzzer will go off (if set to Sound On, see chapter 5.3), and the CF2...
  • Page 12: Service Menu

    Instruction CF-RC Remote Controller The Alarm log saves the latest alarms for later access and easy system failure identification. When no error is causing an alarm, you can access the Alarm log through the Setup menu (see chapter 5.3). 6. Service Menu 6.1 Service...
  • Page 13: Low Energy Optimizer

    Instruction CF-RC Remote Controller 6.1.4 Low Energy Optimizer Menu  Setup  Service  Low Energy Optimizer: Activate Low Energy Optimizer to enter Low Energy Optimizer mode. Press Change to set mode to On or Off. Confirm the setting with Yes. Low Energy Optimizer...
  • Page 14: 2-Pipe

    Instruction CF-RC Remote Controller 6.1.5.1 2-pipe Menu  Setup  Service  Heating/Cooling  2-pipe: Select 2-pipe to configure auto- matic heating/cooling for a 2-pipe system. Heating/Cooling Configuration 2-pipe Change-over Low 22°C Change-over High 26°C Change Back Select Change-over Low or Change-over High to set change-over temperatures. Settings must be between 10 and 50°C with a min.
  • Page 15: Relay Configuration

    Instruction CF-RC Remote Controller 6.1.6 Relay configuration Menu  Setup  Service  Relay configuration: Activate Relay configuration to get a list of connected relays. Relay configuration MC1 Pump MC1-Pump (delay) MC2 Pump MC2-Pump (delay) MC3 Pump MC3-Pump (delay) Boiler MC1-Boiler (no-delay)
  • Page 16: Dew Sensor Power

    Instruction CF-RC Remote Controller 6.1.7 Dew sensor power Menu  Setup  Service  Dew sensor power: Activate Dew sensor power to configure a dew sensor to be powered by CF-MC Master Controller (only output 5 can be used). Status of output 5 is displayed: •...
  • Page 17: Troubleshooting

    Instruction CF-RC Remote Controller 9. Troubleshooting Error Indication Possible Causes Actuator/output (E03) The output of Master Controller or the actuator connected to this output is short-circuited or disconnected. Low temperature (E05) The room temperature is below 5°C. Try to verify the func- tion of the room thermostat by carrying out a link test.
  • Page 18: Figures And Illustrations

    Instruction CF-RC Remote Controller Fig. 1 Fig. 2 Danfoss Heating Solutions VIUHM602 © Danfoss 03/2011...
  • Page 19: Danfoss 03/2011 Viuhm602 Danfoss Heating Solutions

    Instruction CF-RC Remote Controller Fig. 3 Fig. 4 © Danfoss 03/2011 VIUHM602 Danfoss Heating Solutions...
  • Page 20 Danfoss Heating Solutions VIUHM602 © Danfoss 03/2011...