Turbo Mode - Carrier 40MBC-03 Owner's Manual

40mb*c cassette ductless system sizes 09 to 18
Table of Contents

Advertisement

UNIT OFF
a. Set the TIMER to off as described in the UNIT ON
section. The TIMER display on the unit illuminates and
the unit remains off.
b. Adjust the TIMER ON settings to 0.0 to cancel this option.
Timer ON and Timer OFF
Use both functions to program the unit to turn on and shut off at
specified times.
UNIT OFF
a. Set TIMER ON as previously described.
b. Set TIMER OFF as previously described. The unit starts
automatically at the set TIME ON and turns off at the set
TIME OFF.
UNIT ON
a. Set TIME OFF as previously described.
b. Set TIME ON as previously described. The unit turns off
automatically at the set TIME OFF and turns on at the set
TIME ON.
Sleep Mode
The SLEEP mode is used to conserve energy and can be used
when the unit is in the COOL, HEAT or AUTO mode only.
Cool Mode
a. Push SLEEP. After 1 hour the set point raises by 1.8_F
(1_C). After another hour, the set point raises by another
1.8_F (1_C) and the fan runs in a low speed. The unit shuts
off 5 hours after setting the SLEEP mode. The SLEEP
mode cancels if either the "Mode", "TEMP", "Fan", "Timer",
or "On/Off" buttons on the remote control is pressed.
Heat Mode
Same as cooling mode however set points are lowered by 1.8_F
(1_C).

Turbo Mode

Use the TURBO mode to cool or heat the room rapidly.
a. Press TURBO ( an audible "beep" is heard if the indoor unit
supports this function). The fan runs on super high speed.
The TURBO mode terminates automatically 20 minutes after
pushing the TURBO mode button. It can be terminated
immediately by selecting the TURBO mode again. When the
TURBO mode is terminated, the unit reverts to the original
setting.
Self Clean Mode
Press SELF CLEAN to activate or deactivate the self−cleaning
function. Under this function, the air conditioner automatically
cleans and dries the evaporator. The cleaning cycle takes 30
minutes, after which the unit turns off automatically. Pressing
SELF CLEAN on the middle of the cycle cancels the operation
and turn off the unit. This function can be activated only on
COOL or DRY mode.
Follow Me Mode
Press FOLLOW ME to activate or deactivate this function.
Under this setting, the temperature that appears in the remote
control is the actual temperature at its location. The remote
control sends this signal to the air conditioner every 3 minutes.
This function is not available for DRY and FAN modes.
Freeze Protection Mode
Press FP for approximately 2 seconds to activate or deactivate the
freeze protection mode (heating set back). The indoor unit displays
FP.
NOTE: This function is only available in the heating mode.
Under this function, the unit operates at high fan speed and the coil
temperature automatically sets to 46_F (8_C). This mode can also
be deactivated by pressing the "On/Off", "Sleep", "Mode", "Fan",
or either "TEMP" buttons.
Silence Mode
NOTE: The Silence Mode (SLC Button) is not available.
LED Light
Press the LED button to turn the display light on and off.
Resetting the Remote Control
If the batteries in the remote control are removed, the current settings
will be cancelled and the control returns to the initial settings and will
be in standby mode. Push the TURBO button to activate it.
Time Delay
If the ON/OFF button is pressed too soon after a stop, the
compressor will not start for 3 to 4 minutes due to the inherent
protection against frequent compressor cycling. The unit only
emits an audible beep when the signals are received correctly.
Heating Features
If the unit is in the heating mode, there is a delay when the fan
starts. The fan starts only after the coil is warmed up to prevent
cold blow.
Auto Defrost Operation
In heating mode, if the outdoor coil is frosted, the indoor fan and
outdoor fan turns off while the system removes the frost on the
outdoor coil. The system automatically reverts to normal operation
when frost is removed from the outdoor unit.
Auto Start
If the power fails while the unit is operating, the unit stores the
operating condition, and the unit starts the stored operation
automatically when the power is restored.