Drive Status
Pred Fail
Size(MB)
Manage Array Screen
The Manage Array screen enables you to manage the current array. To access the Manage Array
screen, select the appropriate field and press Enter on the Manage Array field from the View Array
screen.
provided the array is made up of 5 disks or fewer. This field is grayed
out under the following conditions:
The device does not meet the minimum requirements for use in an
IM array.
The array already has a hot spare.
The array is made up of the maximum number of devices (6).
The device isn't large enough to mirror existing data on the
primary. The hot spare drive must be greater than or equal to the
size of any drive in any IM volume.
xxxx
OK
Disk is online and fully functional.
Missing
Disk is not responding.
Failed
Disk has failed.
Initalizing
Disk is initializing.
CfgOffln
Disk is offline at host's request.
User Fail
Disk is marked failed at host's request.
Offline
Disk is offline for some other reason.
Inactive
Disk has been set inactive.
Not Syncd
Data on disk is not synchronized with the rest of
the array.
Primary
Disk is the primary disk for a 2 disk mirror and is
OK.
Secondary
Disk is the secondary disk for a 2 disk mirror and
is OK.
Wrg Type
Device is not compatible for use as part of an IM
array.
Too Small
Disk is too small to mirror existing data.
Max Dsks
Maximum # of disks allowed for this type of Array
reached and/or Maximum # of total IM disks on a
controller reached.
No SMART
Disk doesn't support SMART, cannot be used in an
RAID array.
Wrg Intfc
Device interface (SAS) differs from existing IM disks.
Indicates whether device SMART is predicting device failure (Yes, No).
Indicates the size of the device in megabytes (megabyte = 1024 x
1024 = 1,048,576). If the device is part of a two-disk array, this field
reflects the size of the array, not the size of the individual disk. If the
device is part of a three or more disk array, this field is the size that
the disk makes up within the array. When creating a striped array,
the usable size of the array is determined by the number of drives times
the size of the smallest drive in the array. In arrays consisting of
different sized drives, excess space on larger drives are unusable.
Core I/O Card Configuration