Part no. 311-4279300-XXX Product name 機器說明書/GlucoRx HCT/英文(DiME) L148*W105mm/模造紙80P/封:4C,4頁, 內:黑,32頁/共36頁/騎馬釘 Spec Designer Emily C90 M60 Y10 K0 Color C40 M40 Y70 K30 K100...
Page 2
DC) Bio Signal. AC signal works to measure the haematocrit result, and DC measures glucose. Meter then modulates glucose level according to haematocrit value. Effect of haematocrit on accuracy BGM vs. YSI VALUES BEFORE AND AFTER HCT Without 2+2 With 2+2 Before 2+2 After 2+2...
Page 3
It should not be used for the diagnosis of or screening for diabetes mellitus. The test for haematocrit (HCT) as part of the system, is intended for use in the in vitro quantification of packed red blood cell volume fraction in capillary whole blood as an aid in monitoring the status of total volume of red blood cells.
Page 4
10. Proper maintenance and periodic control testing are essential to the longevity of your device. If you are concerned about your accuracy of measurement, please contact GlucoRx Customer care on 01483 755133. KEEP THESE INSTRUCTIONS IN A SAFE PLACE...
TABLE OF CONTENTS BEFORE YOU BEGIN Important Information Contents of System Meter Overview Display Screen Test Strip SETTING THE METER THE THREE MEASURING MODES BEFORE TESTING Calibration How to Code Your Meter (for β-Ketone Test) Checking the Code Number Control Testing Performing a Control Test TESTING WITH BLOOD SAMPLE Preparing the Lancing Device for Blood Testing...
Page 6
SYSTEM TROUBLESHOOTING Result Readings Error Messages Troubleshooting DETAILED INFORMATION SYMBOL INFORMATION SPECIFICATIONS...
BEFORE YOU BEGIN Important Information ● Severe dehydration and excessive water loss may cause readings which are lower than actual values. If you believe you are suffering from severe dehydration, consult a healthcare professional immediately. ● If your blood glucose or β-ketone results are lower or higher than usual, and you do not have any symptoms of illness, first repeat the test.
Contents of System Your new GlucoRx HCT System kit includes: • A meter • Owner’s manual • Protective wallet • Quick start user guide • Daily log book • Warranty card • Lancing device with AST cap • Batteries • Glucose test strips vial •...
Meter Overview Left Side Front Right Side Back Test Strip Slot Insert test strip here to turn the meter on for testing. Display Screen Main Button (M) Enter the meter memory Test Strip Ejector Eject the used strip by pushing up this button. Data Port Download test results with a cable connection.
(for glucose test) (for ketone test) NOTE: The GlucoRx HCT monitor should only be used with GlucoRx HCT Glucose or β-Ketone Test Strips. Using other test strips with this meter can produce inaccurate results.
SETTING THE METER Before using your meter for the first time or if you change the meter battery, you should check and update these settings. Entering the Setting Mode (a) Start with the meter off (no test strip inserted). Press S. 1.
6. Setting the backlight The default setting for meter backlight ("8L") is set to ON. Press M to switch between “On” and “OFF”.Press S. Congratulations! You have completed all settings! NOTE: • These parameters can ONLY be changed in the setting mode. •...
If it matches, you can proceed with your test. If the codes do not match, please stop testing and repeat the calibration procedure. If the problem persists, contact GlucoRx Customer care on 01483 755133 for help.
Test strips (e), control solution (f), lancing device (g) or sterile lancets (h) may not be included in the kit (please check the contents in your product box). They can be obtained separately from GlucoRx Customer care (telephone 01483 755133). Please make sure you have all items needed for a blood glucose or ketone test beforehand.
NOTE: • There is no HCT display function while the meter is in QC mode. • The control test range printed on the test strip vial or individual foil packet is for control testing use only. It is not a recommended range for your blood glucose or ketone level.
TESTING WITH BLOOD SAMPLE WARNING: To reduce the chance of infection: • Never share a lancet or the lancing device. GlucoRx Lancing device is for self-use only. • Always use a new, sterile lancet. Lancets are for single use only.
● Fingertip testing (j) Press the lancing device’s tip firmly against the lower side of your fingertip. Press the release button to prick your finger; a click indicates that the puncture is complete. ● Blood from site other than the fingertip (o) (for β-ketone test) Replace the lancing device cap with the clear cap for AST.
Page 20
5. Read your result The result of your blood glucose test with HCT level or the result of your β-ketone test will appear after the meter counts down to 0. The blood glucose result with HCT level or the β-ketone result will be stored in your memory automatically.
Alternative Site Testing (for β-Ketone Test) In addition to using your fingertips, you can test on your palms. Important: There are limitations with AST (Alternative Site Testing). Please consult your health care professional before you perform AST. Suggested Test Areas for the Hand When to use AST? Food, medication, illness, stress and exercise can affect ketone...
“ ” will appear on the display. Press M again, and the first reading you see is the last blood glucose result along with HCT value, date, time and the measuring mode or you will see the last β-ketone result along with date, time and the measuring mode.
DOWNLOADING RESULTS ONTO A COMPUTER Data Transmission Via Cable You can use your meter with a USB cable and the GlucoRx Healthcare Software System to view test results with HCT levels on your personal computer. To learn more about the GlucoRx Healthcare Software System or to obtain a USB cable separately, please contact GlucoRx Customer care on 01483 755133 for assistance.
MAINTENANCE Battery Your meter comes with two 1.5V AAA size alkaline batteries. Low Battery Signal The meter will display one of the messages below to alert you when the meter power is getting low. 1. The “ ” symbol appears along with display messages: The meter is functional and the result remains accurate, but it is time to change the batteries.
Caring for Your Meter Cleaning ● To clean the meter exterior, wipe it with a disinfecting wipe (Example:Micro-Kill Plus™) to clean exposed surfaces thoroughly and remove any visible dirt, blood or any other body fluid with the wipe. Then dry the device with a soft, dry and clean cloth. Do NOT rinse the meter with water.
● Touch the glucose and ketone test strips with clean and dry hands. ● Use each test strip immediately after removing it from the vial or individual foil packet. ● Write the opening date on the vial label of blood glucose strip when you first opened it.
Important Control Solution Information ● Use only GlucoRx control solution with your meter. ● Do not use the control solution beyond the expiry date or 3 months after first opening. Write the opening date on the control solution vial and discard the remaining solution after 3 months.
SYSTEM TROUBLESHOOTING If you follow the recommended action but the problem persists, please call GlucoRx Customer care on 01483 755133. Result Readings (for glucose test) MESSAGE WHAT IT MEANS Your blood glucose level is below 0.5mmol/L Your blood glucose level is 15mmol/L or more (warning) Your blood glucose level is above 38.9mmol/L...
If the inserted or other coding problem persists, please errors. contact GlucoRx Customer care on 01483 755133 for help. Repeat the test with a new lot of Expired code strip. test strip.
Test strip inserted upside down or Insert the test strip with contact bars incompletely. end first and facing up. Please contact GlucoRx Customer Defective meter or test strips. care on 01483 755133. 2. If the test does not start after applying the sample:...
DETAILED INFORMATION The meter provides you with plasma equivalent results. Normal blood glucose range for people with Time of day diabetes (mmol/L) Fasting and before meal 4 to 7 mmol/L 2 hours after meals< 9 mmol/L Source: Diabetes UK. Blood glucose target. Balance: No.234, 2010 April. P.69 The β-Ketone test measures Beta-Hydroxybutyrate (ß...
SYMBOL INFORMATION SYMBOL REFERENT SYMBOL REFERENT In vitro diagnostic medical Manufacturer device Consult instructions for Serial number Authorised representative Temperature limitation in the European EC REP Community Use by Caution, consult accompanying documents Batch code Collection for electrical Humidity limitation and electronic equipment CE mark...
NOTE SPECIFICATIONS Model No.: TD-4279 Dimension & Weight: 96 (L) x 61 (W) x 26 (H) mm, 67.2 g Power Source: Two 1.5V AAA alkaline batteries Display: LCD Memory: 1000 measurement results with respective date and time External Output: USB Auto electrode insertion detection Auto sample loading detection Auto reaction time count-down...
Page 34
Distributed by GlucoRx Ltd. 4 Wintonlea, Monument Way West, Woking, Surrey, GU21 5EN, UK Website: www.glucorx.co.uk Customer care number: 01483 755133 TaiDoc Technology Corporation B1-7F, No. 127, Wugong 2nd Rd., Wugu Dist., 24888 New Taipei City, Taiwan www.taidoc.com For self-testing...