PTAC Introduction Part 1 General information 1. Model line up ..................12 2. Nomenclature ...................13 3. Appearance..................14 4. List of functions ................15 5. Features ....................16 PTAC...
Page 3
Part 2 Product data 1 YA chassis ..................22 1.1 Features......................22 1.2 List of functions.....................23 1.3 Specifications....................24 1.4 Dimensions ....................30 1.5 Piping diagrams ....................31 1.6 Wiring diagrams....................33 1.7 Capacity tables .....................35 1.8 Electrical characteristics ................43 1.9 Operation range....................44 2 Control Devices................45 2.1 Electronic Controls..................45 PTAC...
Page 4
Part 3 Design and installation 1 General installation procedure............51 2 Installation of unit................52 2.1 Safety precautions ..................52 2.2 Points of explanation about operations ............55 2.3 Selecting installation site for the unit .............55 2.4 Installation of unit...................56 2.5 Wall sleeve installation ..................58 PTAC...
Page 6
Test condition of International Standards 6RWU0-03A Test condition of International Standards AHAM CLASSIFICATION 9306 5151 210/240 1861.1 DB°C(°F) 27.0 27.0 26.7(80) 26.7(80) 27.0 29.0 Indoor Cooling WB°C(°F) 19.5 19.0 19.4(67) 19.4(67) 19.0 19.0 Capacity DB°C(°F) 35.0 35.0 35.0(95) 35.0(95) 35.0 46.0 Outdoor WB°C(°F)
Page 7
Packaged Terminal Air-Conditioners(PTAC) of LG is the best choice a customer can avail when it comes to a quiet environ- ment. Ultra quiet operation is the hallmark of these Air-Conditioners of LG. These range of units are suitable for Hotels and Healthcare applications.
Page 8
Introduction 6RWU0-03A Publication History Pub. No. Frequency Category Product name Refrigerant Notes Published in 6RWU0 - 01A 60Hz PTAC R410A New Edition of PDB Apr.2010 6RWU0 - 01B 60Hz PTAC R410A Spec sheet update June.2010 60Hz PTAC R410A Spec sheet update August.
Page 9
6RWU0-03A Introduction Step by step air conditioner selection process (reference) Calculate or obtain the maximum heat load for the area to be air conditioned. Specifications Model features and functions Air-flow and temperature distribution Selection of the control system Remote Wall Thermostat Control Front Desk Control CAUTION 1.
Part 1 General information 1. Model line up ..................12 2. Nomenclature ..................13 3. Appearance ..................14 4. List of functions ..................15 5. Features ....................16 General information PTAC...
Model line up 6RWU0-03A 1. Model line up Model names Capacity, kW(kBtu/h) Chassis 2.05(7) 2.64(9) 3.52(12) 4.4(15) UYC093ALE31(LP093CD3B) UYC123ALE31(LP123CD3B) UYC073ALE21(LP073CD2B) UYH093ALE31(LP093HD3B) UYH123ALE31(LP123HD3B) UYC153ALE31(LP153CD3B) UYH073ALE21(LP073HD2B) UYC09EALE31(LP096CD3B) UYC12EALE31(LP126CD3B) UYH153ALE31(LP153HD3B) UYH09EALE31(LP096HD3B) UYH12EALE31(LP126HD3B) PTAC General information...
6RWU0-03A List of functions 4. List of functions PTAC Type PTAC Type Category Function Cooling only Models Heat Pump Models Air discharge type Top discharge Top discharge Airflow direction control (up & down) Manual Manual Airflow direction control (left & right)
Features 6RWU0-03A 5. Features The following features can be found in PTAC (Packaged Terminal Air-Conditioners) :- I 2 -Way Air Flow Direction I Two Fan Motors I Washable Filters I LED Diagnostics and Self Diagnostics I Low Noise at High Air Volume I 2 Position Discharge Grille I High Efficiency Compressor I Indoor Room Freeze Protection...
Page 17
New Blowers and Fans which are bigger and stronger than earlier ones operate at low rpm s and have higher efficiency. High Efficiency Compressor LG Rotary compressors have low noise, low vibration and higher efficiency and reliability. Energy save mode This feature employs a programmable logic which enables the unit to minimize power consumption.
Features 6RWU0-03A Electric Heater Electric heaters are used in cold regions when instant heating is required in the room. In such cases, electric heaters are preferred over heat pump models which sometime require long time to achieve the desired heating effect.
Page 19
This feature extends the overall life of the compressor by preventing the short cycling of the air-conditioner. When the com- pressor restarts, LG PTAC is designed to give it a minimum of three minutes to have a time of equalizing the refrigerant pressures for optimizing the cycle.
Formation of ice reduces the airflow through the coil and hence the efficiency of the air conditioning unit. The LG PTHP employs an active reverse cycle defrost function to melt the ice off the outdoor coil for ensuring room comfort conditions and savings from extended operation.
Page 21
6RWU0-03A Part 2 Product data 1 YA chassis ...................22 1.1 Features ......................22 1.2 List of functions ....................23 1.3 Specifications ....................24 1.4 Dimensions.......................30 1.5 Piping diagrams....................31 1.6 Wiring diagrams....................33 1.7 Capacity tables ....................35 1.8 Electrical characteristics ..................43 1.9 Operation range....................44 2 Control Devices..................45 2.1 Electronic Controls ...................45 PTAC Product Data...
6RWU0-03A YA Chassis 1. YA Chassis Models : UYC073ALE21(LP073CD2B) UYC093ALE31(LP093CD3B) UYC123ALE31(LP123CD3B) UYC153ALE31(LP153CD3B) UYH073ALE21(LP073HD2B) UYH093ALE31(LP093HD3B) UYH123ALE31(LP123HD3B) UYH153ALE31(LP153HD3B) UYC09EALE31(LP096CD3B) UYC12EALE31(LP126CD3B) UYH09EALE31(LP096HD3B) UYH12EALE31(LP126HD3B) 1.1 Features I Two Fan Motors I 2 -Way Air Flow Direction I LED Diagnostics and Self Diagnostics I Washable Filters I 2 Position Discharge Grille I Low Noise at High Air Volume I Indoor Room Freeze Protection...
YA Chassis 6RWU0-03A 1.2 List of functions PTAC PTAC Category Function Cooling only Models Heat Pump Models Air flow Air discharge type Top discharge Top discharge Airflow direction control (up & down) Manual Manual Airflow direction control (left & right) Auto swing Airflow steps (fan/cool/heat) 2/2/2...
YA Chassis 6RWU0-03A 1.5 Piping diagrams Models : UYC073ALE21(LP073CD2B) UYC09EALE31(LP096CD3B) UYC093ALE31(LP093CD3B) UYC12EALE31(LP126CD3B) UYC123ALE31(LP123CD3B) UYC153ALE31(LP153CD3B) Liquid side Capillary Tube Heat Heat C.F.F Exchanger Exchanger (Condenser) (Evaporator) Axial Fan High Pressure S/W Compressor Gas side : 41.8/32.6(kgf/cm [595/463(lbf/in LOC. Description PCB Connector Thermistor for indoor Air temperature CN-IDAT2 Thermistor for evaporator temperature...
YA Chassis 6RWU0-03A 1.8 Electrical characteristics Unit Power Compressor Motor FLA Model Voltage Voltage range UYC073ALE21(LP073CD2B) 14.9 15.0 16.0 0.36 0.36 UYC093ALE31(LP093CD3B) 19.5 20.0 19.0 0.36 0.36 UYC123ALE31(LP123CD3B) 19.5 20.0 27.0 0.36 0.36 UYC153ALE31(LP153CD3B) 19.5 20.0 6.55 38.6 0.36 0.36 Min : 187 208~230 Max : 253...
Control Device 6RWU0-03A 2. Control Device 2.1 Electronic Controls The Electronic controls and the panel display is as shown below. FAN SPEED • Every time you push this button, it cycles through the settings as follows: {High(F2) → Low(F1) → High(F2) → Low(F1)} * For Cooling only models(for some specific regions), the “HEAT”...
6RWU0-03A Control Device Additional Controls Additional controls can be seen after removing the front grille and the option cover of the control box. To remove the front grille, pull out the bottom at both the sides and then lift up the grille as shown in the figure on the right. And to install the front grille back to it s original position, place the tabs over the top of the unit and push the bottom of the front grille until the clips snap into place.
Control Device 6RWU0-03A • Remote/Local Control When remote/local switch #1 is on, it allow the unit to operate by the Remote Wall Thermostat. The unit control by knobs are not available. • Energy Saver The energy saver switch #2 is on. This switch is set at cycle fan to provide continuous fan operation in cool or heat modes.
6RWU0-03A Control Device Remote Wall Thermostat When the wires are connected, the unit will be controlled by a remote wall thermostat. The thermostat connections supply the 24 Volt AC. When you install the digital/electronic thermostat, you must set it to 24 Volt AC.
Page 49
Control Device 6RWU0-03A • Electrical Controls Fault Description of Cause of Error Check Point Codes Inspection Indoor air temperature sensor fault is occurred • Check the error after change sensor. Indoor Air CH 01 by indoor air temperature ≤ -35 or the •...
Page 50
Part 3 Design and Installation 1 General installation procedure ............51 2 Installation of unit ................52 2.1 Safety precautions....................52 2.2 Points for explanation about operations ............55 2.3 Selecting installation site for the unit ..............55 2.4 Installation of Unit .....................56 2.5 Wall sleeve installation ..................58 Design and installation PTAC...
General Installation Procedure 6RWU0-03A 1. General Installation Procedure Installation Procedure Remarks …… Check and confirm required load calculation, model Determination of work scope selection etc… …… The base or the foundation of the Air-Conditioner Selection of suitable location should be firm and vibration proof and air-flow should for unit not be restricted on either side of the unit - front and the back.
6RWU0-03A Installation of unit 2. Installation of unit 2.1 Safety precautions To prevent injury to the user or other people and property damage, the following instructions must be followed. I Incorrect operation due to ignoring instructions will cause harm or damage. The seriousness is classified by the following indications.
Page 53
Installation of unit 6RWU0-03A Do not open the inlet grille of the product during operation. • Otherwise it may cause electric shock and failure. If water enters the product, turn off the power switch, remove the power plug from the socket and contact the service center immediately.
Page 54
6RWU0-03A Installation of unit CAUTION Install the product in such a way that the noise or hot wind from the outdoor unit may not cause any distur- bance to neighbors. • Otherwise there may be disputes with neighbors. During installation the unit should be horizontally leveled. •...
Installation of unit 6RWU0-03A 2.2 Points for explanation about operations The items listed under the WARNING and CAUTION list in the operation manual are the items pertaining to possibilities for bodily injury and material damage in addition to the general usage of the product. Accordingly, it is necessary that you make a full explanation about the described contents and also ask your customers to read the owners manual.
Unit With the LG sleeve, you can maintain the best performance of the new air conditioner. If you keep the existing sleeve, you run the risk of poor perfor- mance or product failure.
Page 57
Wall opening 16-1/4"x42-1/4" Recommended To maintain the best performance of LG PTAC 1. An insulation strip must be attached. The insulation strip is provided with the box. 2. After assembly of sleeve & Front grille, the gap should be 20" from both sleeve &...
6RWU0-03A Installation of unit 2.5 WALL SLEEVE INSTALLATION Wall Case Installation Data framing, moving electrical outlets, and other expensive modifications. General Generally, units are installed 3" to 5" above the floor For existing construction it is important that carpentry, (flush to finished floor installation is possible) as near to masonry and electrical work be performed by compe- the center of the room as possible;...
Construction room resulting in increased operating costs and improper As shipped, the LG wall sleeve is ready for installation. room temperature control. Do not remove the stiffener from inside the wall case or the...
Page 60
6RWU0-03A Installation of unit Installation PTAC...
Page 61
Installation of unit 6RWU0-03A PTAC Installation...
6RWU0-03A Installation of unit • unit installation 1. Remove the shipping screw from the ventilation door. 2. Remove the front gille by pulling it out at the bottom to release it, then lift it up along the unit top front. 3.
Installation of unit 6RWU0-03A ELECTRICAL SAFETY IMPORTANT PREFERRED METHOD (PLEASE READ CAREFULLY) FOR THE USER'S PERSONAL SAFETY, THIS APPLI- ANCE MUST BE PROPERLY GROUNDED The power cord of this appliance is equipped with a three- prong (grounding) plug. Use this with a standard three-slot (grounding) wall power outlet to minimize the hazard of elec- Ensure proper ground exists before use...
Controller accessories 6RWU0-03A 1. Controller accessories 1.1 Hard Wire Kit The Hard Wire kit consists of a Junction box which provides a protective enclosure for the electrical connections. This junc- tion box is furnished with approximately 2 - feet of inch flexible steel conduit and a metal box that secures to the PTAC at the control panel.
Page 66
6RWU0-03A Controller accessories 5) Now for 208/230 volt units, remove and discard the white lead from the wire assembly. For 265 volt units, remove and discard the red lead from the wire assembly. * For 208/230 volt units and 265 volt units refer to notes given below. 6) Remove the retaining ring, which holds the threaded conduit and the metal box together, from the straight conduit clamp.
Mechanical accessories 6RWU0-03A 1.2 Wired Wall Thermostat Connection Kit Installation 1. Disconnect power and remove the front panel per unit The PTAC Wire Harness kit provides connection from the 6- installation instruction. pin terminal strip on the PTAC control board to the following board features: 2.
6RWU0-03A Mechanical accessories 2. Mechanical Accessories 2.1 Stamped Aluminum Grille – Single Pack Outdoor Grilles are attached to the Wall Sleeve and exposed to the exterior Wall. These Grilles comes in industry standard size of 42" x 16". These Grilles are of two types : (a) Stamped Aluminum Grille Stamped Aluminum Grille AYRGALA01...
Mechanical accessories 6RWU0-03A 2.2 Remote Escutcheon Kit 3. Lift the cabinet front off the chassis. This kit provides an attractive replacement escutcheon, 4. Lifting the front edge of the escutcheon. (see Figure 1). The kit allows the removal of control knobs and graphics, which are not required when a wall thermo- stat is used to control the unit.
6RWU0-03A Mechanical accessories 2.3 Replacement Filter (10 Pack) The unit is provided with two easy-to-use replaceable mesh filters which can be cleaned periodically form time to time. Replacement Filter 10-Pack AYFT110 2.4 Vent Filter Figure A – Vent (Left side of unit) The Vent filter is used to filter the air flowing inside the room when Air Ventilation is performed by means of the ventilation lever.
Page 71
Yeouido P.O.Box 335 Seoul, 150-721, Korea. http://www.lgeaircon.com All rights reserved The air conditioners manufactured by LG have received ISO9001 certificate for Printed in Korea March/2013 quality assurance and ISO14001 certificate for environmental management system. The specifications, designs, and information in this brochure are subject to...