Opening The Burner; Closing The Burner - Riello RS 300/E LN Installation, Use And Maintenance Instructions

Forced draught gas burners
Table of Contents

Advertisement

6.3

Opening the burner

Disconnect the electrical supply from the burner
DANGER
 Remove the tie rod 1) (Fig. 42) of the head movement lever,
loosening nut 2).
 Disconnect the gas servomotor test point 3).
 Disconnect the gas pressure switch test point 4).
 Remove screws 5).
At this point it is possible to open the burner at the hinge.
20008423
Maintenance
D3818
6.4

Closing the burner

 Close the burner at the hinge.
 Apply screw 5).
 Connect the gas pressure switch test point 4)..
 Connect the gas servomotor test point 3).
 Apply the tire rod 1) (Fig. 42) of the head movement lever,
loosening nut 2).
Connect the electrical supply from the burner.
5
5
3 4
5
1
2
5
34
GB
Fig. 42